LL
Last low temperature
Last low temperature
logged.
LH
Last high temperature
Last high temperature
logged.
Probe fail
PP
Probe short circuit, circuit
open or without probe, or
0
temperature is > 99 C or
0
<-45 C
OPERATING MESSAGES
EP Parameter
6
Function: To end programming.
Once the key is pressed, the indicator goes
into the normal mode and displays the
temperature and all settings are recorded.
T
programming
press "
SET
" key
o end
FS Parameter
5
Function : To restore default settings of the
indicator.
When set to 1 all parameters are programmed to factory set
values.
Useful to debug setting related Problems.
When set to,
0 = FS is disable.
1 = FS as per default value.
Min
Max
Fac.
0
1
0
Password function
In Program mode:
Touch & hold " " key for 2sec. Display will flash "P5"
parameter if "PA" value is kept "0". If other than "0", then "PA'
and "0" will flash. Use " "and " " keys to enter the
password. On entering correct value, display will flash the first
parameter
User can scroll through parameters using
" " or " " keys.
"P5".
High and Low temperature logging function
How to reset the Logged values
While the display is showing the logged values, if user
touches & holds the "
SET
" key for 1sec, the logged values will
be cleared and "
rS
" will be displayed.
Log Values will get reset after Power ON/OFF.
How to see the logged values:
LL : Last Low temperature
LH : Last High temperature
Touch and hold " " key for 1sec. display will flash “LL” and
the corresponding temperature for 4 seconds. After this,
display will flash “LH” and the corresponding temperature for
4 seconds and come out of Log mode and will display
Control probe temperature.
Disclaimer:
This manual & its contents remain the sole property of
PVR CONTROLS . India and shall not be reproduced or
distributed without authorization. Although great care has been
taken in the preparation of this document, the company or its
vendors in no event will be liable for direct, indirect, special,
incidental or consequential damage arising out of the use or
inability to use the product or documentation, even if advised of the
possibility of such damages. No part of this manual may be
reproduced or transmitted in any form or by any means without the
prior written permission of the company. PVR CONTROLS.,
reserves the right to make and changes or improvements without
prior notice.
Warranty:
This product is warranted against defects in materials
and workmanship for a period of one year from the date of
purchase. During the warranty period, product determined by us to
be defective in form or function will be repaired or, at our option,
replaced at no charge. This warranty does not apply if the product
has been damaged by accident, abuse, and misuse or as a result of
service or modification other than by the company. This warranty is
in lieu of any other warranty expressed or implied. In no event shall
the company be held liable for incidental or consequential
damages, including lost revenue or lost business opportunity
arising from the purchase of this product.
Ball Valves
Globe Valves
Hand Valves
Flow Switches
Solenoid Valves
R
Cold Room Controller
Chiller Controller
Two Compressor Controller
Heating Controller
Humidity Controller
Pressure Controller
TM
OUR OTHER PRODUCTS
00 / 19.05.17
7
LP Parameter
4
Min
Max
Fac.
0
1
0
Function: To lock keypad.
Flashing
When locked all parameters can only be viewed, but not
modified.
Note :
If LP parameter is set to 1 and if user tries to change any
parameter value, " LP" will flash on the display.
This parameter is used to lock the keypad so that tampering is
not possible by by-standers.
0 = keypad unlocked
1 = keypad locked