background image

Touch Sensitive Temperature Indicator

TM

SZ-7505T

Operating Instructions

Introduction :

The new SZ-7505T is the next generation of Subzero indicators. Their 
IP ratings are greatly improved and have an excellent iconic display. 
The touch feature whilst increasing reliability also gives a great user 
experience.

Their operation is very user friendly and is easily understood with the 
examples in the instructions below.

The SZ-7505T  can be used as a indicator with a temperature range 

O

O

from -45 C to 99 C. Calibration via keypad is possible.

CAUTION

WIRING:

  The  probe  and  its  corresponding  wires  should

 

never  be 

installed  in  a  conduit  next  to  control  or  power

 

supply  lines.  The 

electrical wiring should be done as shown in the diagram. The power 
supply  circuit  should  be  connected  to  a  protection  switch.  The 
terminals admit wires of upto 2.5sq mm.

WARNING:

    Improper  wiring  may  cause  irreparable  damage  and 

personal  injury.  Kindly  ensure  that  wiring  is  done  by  qualified 
personnel only.

Maintenance:

 Cleaning:   Clean the surface of the indicator   with a 

soft moist cloth. Do not use abrasive detergents, petrol, alcohol or 
solvents.

Notice: 

The  information  in  this  document  is

 

subject

 

  to  change  in 

order to improve reliability , design or function without prior notice and 
does not represent

 

a commitment on the part of the company. In no

 

event will the company be liable for direct, indirect, special, incidental 
or consequential damage arising out of the use or inability to use the 
product or documentation, even if advised of the possibility of such 
damages. No part of this manual may be reproduced or transmitted in 
any form or by any means without the prior written permission of the 
company.

Installation :

 Fixing and dimensions of panel models:

To fix the unit, slide the fastener  1  through the guides  2  as per the 
position shown in the figure. Move the fastener in the direction of the 
arrow, pressing tab  3  it permits to move the fastener in the opposite 
direction of the arrow. 

Indicator 

:  Indicator  should  be  installed  in  a  place  protected  by 

vibration,  water  and  corrosive  gasses  and  where  ambient 
temperature does not exceed the values  specified  in the technical 
data.

Probe :

To give a correct reading, the probe must be installed in a 

place  protected  from  thermal  influences,  which  may  affect  the 
temperature to be controlled. 

71mm

29mm

Panel cutout

3

1

2

36mm

59 mm

10mm

MAX

Panel Cutout and Dimensions :

Side Lock

Indicator 

GASKET

PANEL

Suggested Wiring SZ-7505T (230Vac)

Caution:Wiring for 230Vac load only

TO SZ-T75

5

3

2

1

PROBE

230VAC 
50-60Hz

PHASE

NEUTRAL

USER INTERFACE

UP

In Program mode: 

Scroll through

 

parameters

 & 

parameter value.

 

 

Increases 

Touch and hold for 2sec 

to enter into 

program mode.

In program mode: 

Decreases parameter value

 

PRG

Down/
Program 

In program mode :

set/save the changed value of parameter.

SET

Set

dd Parameter

2

Function : This parameter is used to delay 
the display of temperature by the set in 
this parameter.

Each value corresponds to 5 seconds, if the value is set to 1, it 
corresponds to 5 seconds, if it is set to 2, it corresponds to 10 
seconds and so on.

Min

Max

Fac.

0

36

0

For example, if this parameter is set to 1, temperature on the 
display will be updated after 5 seconds. The same value will be 
considered for calculation and logging.

Display delay parameter is applicable only when temperature 
is increasing (rising). When temperature is decreasing (falling) 
this parameter will not be applicable.
If this parameter is set to 0, this feature will be disabled. 

PA Parameter

3

Min

Max

Fac.

-99

99

0

Function : To change Password.

User cannot enter into program mode, if correct password is 
not entered.

If the password is kept other then 0, user need to enter correct 
password to enter into program mode.

If password is 0, user can directly access program mode.

Min

Max

Fac.

10

O

C

-10

O

C

0

O

C

Function: To set probe calibration.

In time it may be possible that the display may be offset by a 
degree or so.
To compensate for this error, user may need to add or minus 
the degrees required to achieve the correct temperature.

O

Example : 

The temperature on the display is 28 C, whereas 

O

the actual temperature is 30 C. User will have to set the P5 
parameter to 2, which means that once out of the programming 

O

O

O

mode, the temperature on display will be  30 C (28 C+ 2 C).

Touch & hold 

key for 2 seconds.

P5 Parameter

1

Parameter List : 

Suggested Wiring SZ-7505T (12Vac/dc)

TO SZ-T75

5

3

2

1

PROBE

12V

ac/dc

Suggested Wiring SZ-7505T (24V

)

ac/dc

TO SZ-T75

5

3

2

1

PROBE

24V

ac/dc

Housing        

Black ABS  Plastic, Auto-extinguish

Front Cover   

Polycarbonate Plastic

Dimensions  

Frontal : 78 X  36mm,  

  Depth : 59mm

Panel Cutout 

29 X 71mm

Mounting        

Flush panel mounting with fasteners

Protection     

:

 IP65 Front (with gasket)

Connections 

Screw terminal blocks. 

                               

  < 

2.5sq mm terminal only.

Display            

2 X 17mm 7 segment display & 

 

  1 LED for Indication

Data storage 

Non-volatile EEPROM memory

Power input   

:

 230 Vac ±15 %, 50-60Hz. 

  Others on request.

Operating temp. 

0°C to 60°C (non-condensing)

Operating humidity  : 

20% to 85% (non-condensing)

Storage temp  

-25°C to 60°C (non-condensing)

Measuring Range 

-45°C to 99°C

Input                  

NTC probe, SZ-T75

Resolution       

+/-

 

1°C

Accuracy          

+/- 1°C

TECHNICAL DATA

Change Password

Keypad Lock

Restore factory defaults

End Programming

Delay the display of temperature.

INDEX

Sr. 

No.

Para.

Description

1

3

4

5

6

7

P5

Probe calibration.

dd

PA

LP

FS

EP

Password Function
Temperature Logging

2

Operating Messages

Suggested Wiring SZ-7505T (48VDC)

TO SZ-T75

5

3

2

1

PROBE

48VDC

Suggested Wiring SZ-7505T (110Vac)

TO SZ-T75

5

3

2

1

PROBE

110Vac

Reviews: