SITE PREPARATION
CAUTION
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply must be located within the shaded
area shown in the illustration and chart below. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and may
cause interruption of operation.
The electrical outlet must be positioned with the grounding
prong to the right of the thinner blades.
ELECTRICAL REQUIREMENTS
Electrical Supply
115 VAC, 60 Hz
Service
15 amp
Receptacle
3-prong grounding-type
13"
(330)
1
/
4
"
(6)
4
1
/
2
"
(114)
LEFT SIDE
OF OPENING
FLOOR
2
1
/
2
"
(64)
FRONT VIEW
17
1
/
2
"
(445)
4
1
/
2
"
(114)
FRONT VIEW
FLOOR
1
/
4
"
(6)
LEFT SIDE
OF OPENING
2
1
/
2
"
(64)
Electrical—27" models.
Electrical—36" models.