background image

9

A N T I - T I P B R A C K E T

I N S T A L L A T I O N

An anti-tip bracket and hardware is provided
with the Integrated unit. The anti-tip bracket
must be installed on a solid base.

If you are installing the unit in a space deeper
than 24", be sure to locate the anti-tip bracket
so that it engages the unit properly. It is impor-
tant that the anti-tip bracket is placed 24" from
the front of the unit without panels, to the the
back of the anti-tip bracket. Refer to illustra-
tions 1 and 2 below and note that for 27" (686)
wide units dimension A is 13

1

/

2

" (343), and 18"

(457) for 36" (914) wide units.

W O O D   F L O O R   A P P L I C A T I O N S

Use the six #12 x 2

1

/

2

" wood screws and the

six 

1

/

4

" flat washers provided. Drill pilot holes

3

/

16

" (5) diameter maximum, and be sure that

the screws penetrate through the flooring
material and into the wall plate a minimum of

3

/

4

" (19). Be sure that the screws hold tight.

Refer to illustration 1 below.

C O N C R E T E   F L O O R   A P P L I C A T I O N S

Use the two 

3

/

8

" x 3

3

/

4

" concrete wedge

anchors, two # 12 x 2

1

/

2

" wood screws and two

1

/

4

" flat washers provided. Be sure that the

anchors and screws hold tight. Refer to
illustration 2 below.

IMPORTANT NOTE: In some installations the
subflooring or finished floor may require
angling the wood screws used to fasten the
anti-tip bracket to the back wall. Refer to
illustrations 1 and 2.

I N T E G R AT E D  

I N S T A L L A T I O N   I N S T R U C T I O N S

To prevent the unit from tipping forward
and provide a stable installation, the unit
must be secured in place with the anti-tip
blocking bracket.

Make sure that there are no electrical
wires or plumbing in the area which the
screws could penetrate.

WOOD FLOOR 

Finished Flooring 

Underlayment 

Subflooring 

Wall Plate 

Finished Flooring 

Underlayment 

Subflooring 

Wall Plate 

CONCRETE 
FLOOR 

1

1

/

2

"

min 

(38)

Illus. 1

Illus. 2

S P E C I F I C A T I O N S

Dimension A

27" (686) Wide Units

13

1

/

2

" (343)

36" (914) Wide Units

18" (457)

Summary of Contents for 700BC

Page 1: ...INSTALLATION INSTRUCTIONS I N T E G R A T E D R E F R I G E R A T I O N ...

Page 2: ...s informa tion that is especially relevant to a problem free installation signals a situation where minor injury or product damage may occur if you do not follow instructions states a hazard that may cause serious injury or death if precautions are not followed C O N T E N T S Installation Recommendations 3 Installation Specifications 4 Installation Instructions 7 Installation Checklist 18 Service...

Page 3: ...process it is recommended that you read this entire Installation Instructions book There are key details that you should take special care to observe during the installation By reading these instructions carefully you will make the installation process easier problem free and most importantly safe Any questions or problems about the installation should be directed to your Sub Zero dealer or the Su...

Page 4: ...ING FORWARD 41 2 114 21 2 64 151 2 394 3 4 19 3 76 1 4 6 13 330 9 229 ANTI TIP BRACKET LOCATE WATER LINE REAR ENTRY WITHIN SHADED AREA LOCATE ELECTRICAL WITHIN SHADED AREA ORIENT GROUND PRONG TO RIGHT AS SHOWN PLACEMENT OF THE ANTI TIP BRACKET SHOULD BE 24 610 FROM THE FRONT OF THE UNIT WITHOUT PANELS TO THE BACK OF THE ANTI TIP BRACKET I N S T A L L A T I O N Models 700TR 700TF I and 700TC I Mode...

Page 5: ... 131 2 343 18 457 ANTI TIP BRACKET 18 457 6 152 TOP VIEW TOP VIEW SIDE VIEW FRONT VIEW WATER LINE SIDE ENTRY LOCATION ANTI TIP BRACKET 21 2 64 20 508 3 4 19 3 76 171 2 445 131 2 343 ANTI TIP BRACKET NOTE ANTI TIP BRACKET MUST BE INSTALLED TO PREVENT UNIT FROM TIPPING FORWARD 41 2 114 1 4 6 LOCATE WATER LINE REAR ENTRY WITHIN SHADED AREA LOCATE ELECTRICAL WITHIN SHADED AREA ORIENT GROUND PRONG TO R...

Page 6: ...STALLED TO PREVENT UNIT FROM TIPPING FORWARD 41 2 114 21 2 64 151 2 394 3 4 19 3 76 1 4 6 13 330 9 229 ANTI TIP BRACKET LOCATE WATER LINE REAR ENTRY WITHIN SHADED AREA LOCATE ELECTRICAL WITHIN SHADED AREA ORIENT GROUND PRONG TO RIGHT AS SHOWN I N S T A L L A T I O N Models 700BR 700BF I and 700BC I Models without an ice maker will not require the water line connection O V E R A L L D I M E N S I O...

Page 7: ...use water supply Use an easily accessible shut off valve between the water supply and the unit This shut off valve should not be installed behind the unit Do not use self piercing valves A saddle valve kit part 4200880 is available from your Sub Zero dealer The Installation illustrations on pages 4 6 show the precise placement of the water line When routing through the side walls you must place th...

Page 8: ...t attaching to a side wall or you are installing two Integrated units together you must remove the clips before moving the unit into place After removing the clips replace the screws in the holes and discard the clips Optional components are necessary for anchoring two Integrated units together Refer to Dual Installations on page 17 Optional installation components are available through your Sub Z...

Page 9: ...ure that the screws hold tight Refer to illustration 1 below C O N C R E T E F L O O R A P P L I C AT I O N S Use the two 3 8 x 33 4 concrete wedge anchors two 12 x 21 2 wood screws and two 1 4 flat washers provided Be sure that the anchors and screws hold tight Refer to illustration 2 below IMPORTANT NOTE In some installations the subflooring or finished floor may require angling the wood screws ...

Page 10: ...ide molding pieces and the kickplate grille IMPORTANT NOTE If two Integrated units are installed closer than 2 51 to one another it is necessary to use the Sub Zero dual installation heater kit Refer to Dual Installations on page 17 for additional information The heater plate from this kit must be attached to the left side exterior of the right hand unit before the units are slid into position INT...

Page 11: ...T R U C T I O N S CO LDE R WA RM ER REF RIG ERA TO R FRE EZE R CO LDE R WA RM ER ICE ON O FF ON O FF UN IT ON O FF Unit On Off Unit On Off Shut off the power to the electrical outlet Before moving the Integrated unit into position tape down the water supply line for the ice maker so it will stay in place as you move the unit Refer to the Installation illustration for your unit on pages 4 6 for pla...

Page 12: ...oil base high gloss enamel paint INTEGRATED I N S TA L L AT I O N I N S T R U C T I O N S LEVEL T H E U N I T Level the Integrated unit by turning the front leveling legs clockwise to raise the unit or counterclockwise to lower it To assist you in adjusting the front leveling legs up or down use a standard screwdriver blade and place it in the front leveling leg as shown in illustration 6 below Th...

Page 13: ...e quick connect water valve and PEX tubing are located on the right hand side of the unit towards the bottom Follow these instructions to connect the ice maker water line Attach the union fitting to the copper house water supply line Pull the coiled gray PEX tubing with a red cap and captured metal nut toward the house water supply line Remove and discard the red cap then attach the tubing to the ...

Page 14: ... E N T S Door and drawer panels must be a minimum of 5 8 16 thick The door panel cannot exceed 40 lbs 18 kg and each drawer panel must not exceed 12 lbs 5 kg for 27 686 wide units For 36 914 wide units the door panel weight limit is 53 lbs 24 kg and 16 lbs 7 kg for each drawer panel KICKPLATE GRILLE I N S TA L L AT I O N Once your Integrated unit is secured the kickplate grille can be installed Th...

Page 15: ...verall size of the panel shown in illustra tion 13 is the minimum size necessary to cover the door of the unit The exact measurements of your door panel may vary depending on the particular installation you are following Once you have located the proper position for the bracket mark the pilot holes remove the template and drill pilot holes for mounting the bracket It is best to start with a few ho...

Page 16: ... drawer panel must not exceed 12 lbs 5 kg for 27 686 wide units For 36 914 wide units the door panel weight limit is 53 lbs 24 kg and 16 lbs 7 kg for each drawer panel PANEL I N S TA L L AT I O N Before attaching the door panel to the door remove the outer screws from each of the three mounting positions along the hinge side of the door Unscrew the three remaining screws in the center of each moun...

Page 17: ... O N S When two Integrated units are installed closer than 2 51 to one another it is necessary to use the Sub Zero dual installation heater kit BBDUAL or TTDUAL The heater plate from this kit must be attached to the left side exterior of the right hand unit before the units are slid into position Contact your Sub Zero dealer for the proper components and installation instructions For questions rel...

Page 18: ... S T Has the anti tip bracket been installed properly and is it making contact with the unit Is the unit level Are all leveling legs making contact with the floor Is the power cord plugged into a properly grounded 3 prong outlet which has been installed in accordance with all applicable electrical codes Is the water supply connected for units with an automatic ice maker Have you checked for leaks ...

Page 19: ...he cabinet to the left of the upper drawer 19 If you are storing or disposing of your old refrigerator or freezer please do it safely Remove the doors or tightly secure the doors closed Child entrapment accidents can be tragic C O N TA C T I N F O R M AT I O N Sub Zero Customer Service 800 222 7820 Website subzero com SERVICE I N F O R M AT I O N The information and images in this book are the cop...

Page 20: ...7 0 0 2 1 2 8 6 2 0 0 6 S U B Z E RO F R E E Z E R C O M PA N Y I N C P O B OX 4 4 1 3 0 M A D I S O N W I 5 3 7 4 4 4 1 3 0 8 0 0 2 2 2 7 8 2 0 S U B Z E RO C O M ...

Reviews: