PURE SINE WAVE HOME UPS
OUTPUT
OUTPUT
INV
(RED)
RED
(BLACK)
BLACK
BATTERY WIRES
UPS
NC
HC
1
2
6
+
_
3
4
5
(3)
Back
Panel
The
has two battery wires coming out from the rear side, a Fuse
Holder, two toggle switches, an output Socket and an input mains Cable
. Connect the two battery wires to the terminals of the
battery, the red colored to the positive terminal and black colored to the
negative one. A three core input cable is used to connect the
to
incoming AC Mains. Ensure that incoming phase (or line) is connected to
line (Red wire), neutral is connected to neutral (Black Wire) and earth is
connected to earth (Green Wire). After this the output is connected
through the output socket at the rear of the
Home UPS
(or
input terminal block)
home UPS
the
Home UPS.
REAR VIEW:
BACK PANEL:
Note :
REV.08-06-07
1. Position the Toggle Switch(4) at the rear panel to Narrow Window
(UPS) mode if you want to run PC load otherwise always place the
switch to Wide Window (INV) mode.
2. Position the Toggle switch(5) to HC mode during frequent power cuts
for fast charging of battery otherwise place to NC mode.
GREEN
1
. 3 Core Input Wire (Mains Input for Home UPS).
2.
15
A AC Output Socket.
3. F
6.3
A/
250
V (Fast Blow) Fuse.
4. Toggle Switch for Narrow Window (UPS) /
Wide Window (INV) mode.
5. Toggle Switch for Normal Charging Current (NC) /
High Charging Current (HC) mode.
6. Battery Wires
1
m long.
Back panel view
800
VA