Model 50/51 User Guide
Issue 6, September 2004
Studio Technologies, Inc.
Page 45
Function: Set Dim Level
Byte Value Description
1 F0H
System-Exclusive
Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
01H
Product ID (Model 50)
6
10H
Function: Set Dim Level
7
0nH
Status, Range 0-5:
0=full
mute
(approx.
70dB)
1=30dB
dim
2=25dB
dim
3=20dB
dim
4=15dB
dim
5=10dB
dim
8
F7H
EOX, End of System Exclusive