Issue 4, August 2021
Model 5401A User Guide
Page 32
Studio Technologies, Inc.
Model 5401A
DANTE LEADER CLOCK
depend on the network configuration as selected
using the Dante Controller application. The choices
are Switched, Redundant, SMgmt, and
ReMgmt.
Switched Network Operation
PRI LED: The PRI LED will light red when no Ethernet
connection is present on the Dante primary or Dante
secondary Ethernet ports. It will light green whenever
a Gigabit Ethernet connection is present on either the
Dante primary or the Dante secondary Ethernet port
and a link has been established. It will light orange
whenever a 100 Mb/s Ethernet connection is present
on either the Dante primary or the Dante secondary
Ethernet port and a link has been established.
SEC LED: The SEC LED will not light.
MGMT LED: When no Ethernet connection is present
on the management Ethernet port the MGMT LED
will not light. It will light green whenever a Gigabit or
100 Mb/s Ethernet signal is connected and a link has
been established.
Redundant Network Operation
PRI LED: The PRI LED will light red when no Ethernet
connection is present on the Dante primary Ethernet
port. It will light green whenever a Gigabit Ethernet
connection is present on the Dante primary Ethernet
port and a link has been established. It will light orange
whenever a 100 Mb/s Ethernet connection is present
and a link has been established.
SEC LED: The SEC LED will light red when no Eth-
ernet connection is present on the Dante secondary
Ethernet port. It will light green whenever a Gigabit
Ethernet connection is present on the Dante second-
ary Ethernet port and a link has been established. It
will light orange whenever a 100 Mb/s Ethernet con-
nection is present and a link has been established.
MGMT LED: When no Ethernet connection is present
on the management Ethernet port the MGMT LED will
not light. It will light green whenever a Gigabit or 100
Mb/s Ethernet connection is present and a link has
been established.
SMgmt Network Operation
PRI LED: The PRI LED will light red when no Ethernet
connection is present on the Dante primary or Dante
secondary Ethernet ports. It will light green whenever
a Gigabit Ethernet connection is present on the Dante
primary or Dante secondary Ethernet ports and a link
has been established. It will light orange whenever
a 100 Mb/s Ethernet connection is present on either
Ethernet port and a link has been established.
SEC LED: The SEC LED will not light.
MGMT LED: The MGMT LED will not light if an
Ethernet connection is not present on the Dante
primary or Dante secondary Ethernet ports. It will
light green whenever a Gigabit or 100 Mb/s Ethernet
connection is present on either the Dante primary or
Dante secondary Ethernet port and a link has been
established.
ReMgmt Network Operation
PRI LED: The PRI LED will light red when no Ethernet
connection is present on the Dante primary Ethernet
port. It will light green whenever a Gigabit Ethernet
connection is present on the Dante primary Ethernet
port and a link has been established. It will light orange
whenever a 100 Mb/s Ethernet connection is present
on the Dante primary Ethernet port and a link has
been established.
SEC LED: The SEC LED will light red when an Ether-
net connection is not present on the Dante secondary
Ethernet port. It will light green whenever a Gigabit
Ethernet connection is present on the Dante second-
ary Ethernet port and a link has been established. It
will light orange whenever a 100 Mb/s Ethernet con-
nection is present on the Dante secondary Ethernet
port and a link has been established.
MGMT LED: The MGMT LED will not light if an Eth-
ernet connection is not present on the Dante primary
Ethernet port. It will light green whenever a Gigabit
or 100 Mb/s Ethernet connection is present on the
Dante primary Ethernet port and a link has been
established.
Dante LEDs
Two LEDs are associated with the Model 5401A’s
Dante interface. The system LED, labeled SYS, and
the synchronization LED, labeled SYNC, will both light
red as the Model 5401A’s Dante interface starts to
function and awaits connection and full operation with
one or two local area networks (LANs). (Two networks
are utilized only when Dante redundancy is enabled.)
The SYS LED will light red to indicate that the Dante
interface is not ready to pass data to other devices. It