STUDIO DUE 1950 User Manual Download Page 4

rel. 03/22  -  Studio Due

4

..................................................................................................................  ENG

SAFETY INFORMATION (service personnel)

IMPORTANT !

READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT.
INSTRUCTION TO PREVENT INJURY OR DAMAGE DUE TO ELECTRIC SHOCK, FIRE, MECHANICAL HAZARDS, DANGEROUS MATTERS.

• PROTECTION AGAINST DANGEROUS MATTERS

At the end of its life, must be collected separately. It shouldn’t be thrown as urban waste and neither released in the environment.
It must be collected from the nearest special waste collection point or consigned to your dealer that provides the service. 
The incorrect waste disposal can damage the environment and the people for the presence of dangerous substances. 
Sanctions are provided for an unauthorized disposal.  ............................................................................................................................................................

• PROTECTION AGAINST FIRE

1) Maintain minimum distance of 0,2 meter to lighted objects.
2) Replace fuses (if present) only with the specified type and rating.
3) Do not install the fixture close to heat sources. Do not lay the connection cable on the fixture when it is warm.
4) Fixture designed to be installed on normally flammable surfaces.   .....................................................................................................................................

• PROTECTION AGAINST ELECTRIC SHOCK

1) This equipment must be earthed.
2) Class I equipment. The power supply cord includes a protective earthing conductor as part of the cord.
3) Disconnect power before servicing (service personnel).
4) To replace the LEDs, contact: Studio Due Srls.
5) If the external flexible cable of this appliance is damaged, it must only be replaced by the manufacturer, 
    its assistance service, or equivalent qualified personnel, in order to avoid dangers.   ...........................................................................................................

• PROTECTION AGAINST MECHANICAL HAZARDS

1) Use secondary safety chain when fixing this equipment.
2) The protection screens and the lenses must be replaced with genuine parts only if they are visibly damaged and 
    their effectiveness has been reduced, for example, by cracks or deep scratches.
3) Do not look directly into the illuminated LEDs of the product for long periods of time. LED lamps can cause eye 
    damage or irritation. Do not look directly into the light source using an optical instrument that focuses on the light beams.
    The device should be positioned so that there is no prolonged observation of the device at a distance of less than 100cm. (RG1 – IEC/TR  62778:2014).

...................................................................................................................  ITA

INFORMAZIONI DI SICUREZZA (personale di servizio)

IMPORTANTE !

LEGGERE ATTENTAMENTE TUTTI GLI AVVERTIMENTI PRIMA DI COMPIERE QUALUNQUE OPERAZIONE SU QUESTO APPARECCHIO.  
ISTRUZIONI PER PREVENIRE LESIONI O DANNI DOVUTI AL FUOCO, ALLE SCOSSE ELETTRICHE, AI RISCHI MECCANICI ED A SOSTANZE PERICOLOSE.

•PROTEZIONE CONTRO SOSTANZE PERICOLOSE                                

A fine vita è oggetto di raccolta separata, non gettare nei comuni cassonetti di rifiuti urbani, né tantomeno nell’ambiente. 
Può essere consegnato presso i centri di raccolta delle amministrazioni comunali, oppure presso i rivenditori che forniscono questo servizio. 
Lo smaltimento errato può causare danni alle persone e all’ambiente per la possibile presenza di sostanze pericolose. 
Sono previste sanzioni in caso di smaltimento abusivo dei suddetti prodotti.  ..........................................................................................................................

•PROTEZIONE CONTRO IL FUOCO

1) Mantenere la distanza minima di 0,2 metri dagli oggetti illuminati.
2) Sostituire i fusibili (se presenti) solo con altri dello stesso tipo e valore.
3) Non installare il faro vicino fonti di calore. Non appoggiare il cavo di connessione sul faro quando questo è caldo.
4) Questo apparecchio è adatto per il montaggio su superfici normalmente infiammabili.  .......................................................................................................

•PROTEZIONE CONTRO SCOSSE ELETTRICHE

1) Questo apparecchio necessita di messa a terra.
2) Apparecchio di Classe I. Il conduttore di protezione deve far parte del cavo di alimentazione.
3) Disconnettere l’alimentazione prima di aprire l’apparecchio (personale di servizio).
4) Per la sostituzione dei LED contattare l’azienda: Studio Due Srls
5) Se il cavo flessibile esterno di questo apparecchio è danneggiato, deve essere sostituito esclusivamente 
    dal costruttore, dal suo servizio di assistenza, o da personale qualificato equivalente, al fine di evitare pericoli.  .................................................................

•PROTEZIONE CONTRO RISCHI MECCANICI

1) Usare la catena di sicurezza supplementare quando installate l’apparecchio.
2) Gli schermi di protezione e le lenti devono essere sostituiti sempre con ricambi originali se sono visibilmente danneggiati 
    e se la loro efficacia è stata ridotta, per esempio, da fessure o incisioni profonde.
3) Non guardare direttamente nei LED illuminati del prodotto per lunghi periodi di tempo. Le lampade a LED possono 
    causare danni o irritazione agli occhi. Non guardare direttamente nella sorgente luminosa utilizzando uno strumento 
    ottico che si concentra sui fasci di luce. L’apparecchio dovrebbe essere posizionato in modo che non sia prevista 
    un’osservazione prolungata dell’apparecchio ad una distanza inferiore di 100cm. (RG1 – IEC/TR  62778:2014).

Summary of Contents for 1950

Page 1: ...User manual for art 1950 1951 1952 Manuale d uso per art 1950 1951 1952 MONOCHROMATIC series Stadio ...

Page 2: ...Protection Module capable of withstanding voltage and current pulses up to 10 000Volt and 20 000Ampere tutta la serie Elevata immunità ai sovraccarichi di tensione grazie all utilizzo di un Modulo di Protezione contro le Sovratensioni 10KV 20KA in grado di sopportare impulsi di tensione e corrente fino a 10 000 Volt e 20 000 Ampere 10KV 20KA 10 000Volt 20 000Ampere ...

Page 3: ...lla fonte di alimentazione Page 10 DALI or DMX connections Connessioni DALI o DMX Page 11 Box driver heads connections Connessioni scatola driver teste Page 12 Mounting scheme Schema di montaggio Page 13 DMX channels Canali DMX Page 14 Example of connections DMX Controller Esempi di collegamento DMX Controller Page 15 DRS Setup configuration Configurazione DRS Setup Page 18 Physical Dimensioni Page ...

Page 4: ...E LEGGERE ATTENTAMENTE TUTTI GLI AVVERTIMENTI PRIMA DI COMPIERE QUALUNQUE OPERAZIONE SU QUESTO APPARECCHIO ISTRUZIONI PER PREVENIRE LESIONI O DANNI DOVUTI AL FUOCO ALLE SCOSSE ELETTRICHE AI RISCHI MECCANICI ED A SOSTANZE PERICOLOSE PROTEZIONE CONTRO SOSTANZE PERICOLOSE A fine vita è oggetto di raccolta separata non gettare nei comuni cassonetti di rifiuti urbani né tantomeno nell ambiente Può essere...

Page 5: ...anual Studio Due warranty CE standards ITA INTRODUZIONE CONTROLLATE CHE L APPARECCHIO NON ABBIA SUBITO ALCUN DANNO DURANTE IL TRASPORTO SE AVESSE SUBITO DEI DANNI O SE NON DOVESSE FUNZIONARE RIVOLGETEVI AL VOSTRO RIVENDITORE SE L APPARECCHIO VI È STATO SPEDITO DIRETTAMENTE RIVOLGETEVI SUBITO ALLA DITTA DI TRASPORTO SOLO IL DESTINATARIO LA PERSONA O DITTA RICEVENTE L APPARECCHIO PUÒ RECLAMARE PER Q...

Page 6: ... lens for 15 beam art KB50 30bl 50x50mm lens for 30 beam art KB50 50bl 50x50mm lens for 50 beam art CLAMP C professional aluminium clamp all fixtures art SAFETY CHAIN for STADIO 432 only safety steel chain art SAFETY WIRE C for STADIO 288 and 144 safety steel cable black color plastic protection ...

Page 7: ...10KV Voltage range 90 305VAC 47 63Hz Active Power Factor PF 0 95 230V Current 3 1 230V 6A 120V Power 700W max DMX channels 1 Physical 820x180x455 mm Weight 21 Kg ITEM STADIO 432 KEY features 3 HEADS LEDs 432 high power NICHIA NVSW319 Expected lifetime 50 000 hrs Color temperature 5750K on request 3000K 4000K CRI 75 on request 80 and 90 Efficency 140lm W Lumen 150 000 Optics PMMA 8N and ultra white ...

Page 8: ...mpered glass 15 lenses On request 30 50 120 Power supply Surge Protection line line and line earth 10KA 8 20uS 10KV Voltage range 90 305VAC 47 63Hz Active Power Factor PF 0 95 230V Current 1 55 230V 3A 120V Inrush current 120A 230V Power 350W max DMX channels 1 Physical 768x136x310 mm Weight 10 Kg head 3 Kg power box art 1952 STADIO 144 RDM made in Italy SN QC WI FI n 144 LEDs 5000K Optics DMX RDM...

Page 9: ...ecchio in caso di sostituzione del cavo di alimentazione fare riferimento alla TABELLA SEZIONE CONDUTTORE ATTENTION HIGH VOLTAGE ALWAYS DISCONNECT THE MAINS SUPPLY BEFORE ACCESS TO THE CONNECTION AREA ATTENZIONE ALTA TENSIONE SCOLLEGARE SEMPRE L ALIMENTAZIONE PRIMA DI APRIRE IL VANO DEI COLLEGAMENTI CONDUCTOR SIZES SEZIONE CONDUTTORE length lunghezza 20mt MAINS VOLTAGE CROSS SELECTIONAL AREAS 100 ...

Page 10: ...ncorretto o il mancato collegamento del terminale di linea è probabilmente la più comune causa del difettoso funzionamento della linea DMX Il terminale di linea DMX consiste in una resistenza posta alla fine della linea vedere fig 1 La resistenza terminale dovrebbe avere lo stesso valore dell impedenza del cavo di collegamento 120 Ohm E raccomandato per tutti i sistemi DMX 512 di inserire il teminal...

Page 11: ...NG ITA CONNECTION FROM THE BOX TO THE HEADS CONNESSIONE DALLA SCATOLA ALLE TESTE RED POLARITY BLACK POLARITY GREEN YELLOW GROUND WARNING HIGH TENSION 4 x 450 VDC ATTENZIONE ALTA TENSIONE 4 x 450 VDC G L N FEMALE MALE IF YOU NEED TO MAKE ADDITIONAL CONNECTION CABLES C FOLLOW THE DESCRIBED SPECIFICATIONS SE DOVETE REALIZZARE DEI CAVI DI COLLEGAMENTO AGGIUNTIVI C SEGUIRE LE SPECIFICHE DESCRITTE L N G...

Page 12: ...L MURO MAIN IN Ingresso rete DMX IN and DMX OUT Standard 3x1 5mm cable Cavo standard 3x1 5mm Standard DMX cable Cavo standard DMX DRIVER BOX SCATOLA DRIVER DRIVE BOX SCATOLA DRIVER 668x245x80mm Standard 3x1mm cable 2 colours green yellow Cavo standard 3x1mm 2 colori giallo verde ENG ITA CONNECTION SCHEME SCHEMA DI MONTAGGIO Additional connection cable C Cavo di connessione addizionale C C ...

Page 13: ... FUNCTION 0 31 63 95 127 159 191 233 255 CH1 DIMMER DIMMER from 20 to 100 on CH1 ENG ITA DMX CHANNELS and DALI LINE CANALI DMX e LINEA DALI DMX line for Dimmable version setting 1ch linea DMX versione Dimmerabile settaggio 1ch 20 100 DALI ...

Page 14: ...linea di uscita DMX 512 lunga oltre 150 mt LINE 150 mt with microphonic or audio cable LINEA 150 mt con cavo microfonico o audio DMX Example 3 Esempio 3 SIGNAL AMPLIFIER AMPLIFICATORE DI SEGNALE DMX out DMX out TL Terminal Line for example fixture set up at 3 channels TL TL TL TL fixture apparecchio fixture apparecchio fixture apparecchio fixture apparecchio fixture apparecchio fixture apparecchio fixture...

Page 15: ...ave function The device is powered through battery DRS è il nuovo concetto dell illuminazione LED per uso professionale nelle installazioni esterne permanenti Gli apparecchi LED possono essere controllati e configurati tramite uno specifico controller il DRS DMX Remote Setup il quale consente di programmare e configurare scene e giochi di luce in modalità remota Questi apparecchi LED hanno installati...

Page 16: ... Il pulsante ENTER permettere di entrare in un menu o di confermare una opzione in caso di lampeggio del parametro Il pulsante ESC annulla una operazione o torna al livello di menu inferiore ENG SETUP AND CONFIGURATION BY DRS DMX REMOTE SETUP To make the set up of the various fixture parameter proceed as follow Disconnect the fixture to set up from the other DMX RDM devices Connect the DMX cable of ...

Page 17: ...e al quale è stato associato Wireless bridge ULbr If wireless is ON enable the transmission of the received data by cable to the other fixtures Se il wireless è attivo consente la trasmissione dati agli altri apprecchi collegati via cavo ON OFF Smooth Dimming SMth Set the interpolation type for the smooth dimming function Imposta il tipo di interpolazione per la funzione smooth dimming OFF Sd1 Sd2 ...

Page 18: ...rel 03 22 Studio Due 18 PHYSICAL DIMENSIONI STADIO 432 816 690 560 100 ...

Page 19: ...rel 03 22 Studio Due 19 820 455 290 180 768 310 136 STADIO 288 STADIO 144 ...

Page 20: ... 30 EU EN 61000 3 2 2014 EN 61000 3 3 2013 EN 61547 2009 EN 55103 2 2009 EN 55015 2013 EN 55103 1 2009 A1 2012 Low Voltage Directive 2014 35 EU EN 60529 1991 A1 2000 A2 2013 EN 62471 2008 EN 60598 1 2015 EN 60598 2 17 1989 A2 1991 La ditta The firm dichiara sotto la propria responsabilità che il prodotto declare under our sole responsability that the product VITERBO 13 06 19 19 Data di apposizione...

Page 21: ... 30 EU EN 61000 3 2 2014 EN 61000 3 3 2013 EN 61547 2009 EN 55103 2 2009 EN 55015 2013 EN 55103 1 2009 A1 2012 Low Voltage Directive 2014 35 EU EN 60529 1991 A1 2000 A2 2013 EN 62471 2008 EN 60598 1 2015 EN 60598 2 17 1989 A2 1991 La ditta The firm dichiara sotto la propria responsabilità che il prodotto declare under our sole responsability that the product VITERBO 13 06 19 Doc 1951 REV 1 06 19 S...

Page 22: ... 30 EU EN 61000 3 2 2014 EN 61000 3 3 2013 EN 61547 2009 EN 55103 2 2009 EN 55015 2013 EN 55103 1 2009 A1 2012 Low Voltage Directive 2014 35 EU EN 60529 1991 A1 2000 A2 2013 EN 62471 2008 EN 60598 1 2015 EN 60598 2 17 1989 A2 1991 La ditta The firm dichiara sotto la propria responsabilità che il prodotto declare under our sole responsability that the product VITERBO 13 06 19 Doc 1952 REV 1 06 19 S...

Page 23: ...aggio Il costo di imballaggio è del 2 sul prezzo netto per tutti gli articoli Detti prezzi possono essere soggetti a possibili variazioni per eventuali aumenti dei costi di produzione o imposte La merce viaggia a rischio e pericolo del committente anche se in porto franco Reclami per possibili danni durante il trasporto dovranno essere fatti esclusivamente al vettore Eventuali osservazioni sulle m...

Page 24: ... essere soggette a variazioni senza preavviso Head Office STUDIO DUE s r l I Str Poggino 100 01100 Viterbo Italy tel 39 0761 352520 fax 39 0761 352653 info studiodue com www studiodue com for technical info service studiodue com STUDIO DUE UK 3 Encon Court Owl Close Moulton Park Industrial Estate Northampton England UK NN3 6 HZ tel 44 1933 650 820 info studiodue co uk ...

Reviews: