Vista 5 M3 Digital Mixing System
GC Operation 4-107
Document generated: 28.08.13
SW V4.9
Metering / Overload LED
If ‘Shows Entering Headroom’ is ticked, the Overload LEDs on the channel
strips as well as the red overload sign on the TFT screens illuminates when
the signal level enters the headroom set with ‘Headroom Threshold’ instead
of an overload condition.
Metering / Headroom Threshold
The desired headroom can be set here; this setting doesn’t make any level
changes but just sets the threshold level of the bargraph meters. Default set-
ting: –9 dB
FS
, i.e. 9 dB below clipping occurs.
Metering / Meter History
This slider allows setting the speed of the meter history view in four steps
from 0.5 s/div (fastest) to 5 s/div (slowest). Default: 1 s/div.
Generator / Level
Sets the test signal generator’s level to the desired value. Levels can be set
to off and, in 1 dB steps, from –90 to +10 dB
FS
. The Generator Level can be
turned off by moving the Level slider all the way to the left.
Generator / Frequency
Sets the test signal generator’s frequency (sine wave only) to the desired value.
The generator frequency can be set in 1/12
th
octave steps from 19.95 Hz to
19.95 kHz.
Generator / Signal
Selects the waveform of the test signal generator, from Sine Wave, White
Noise, and Pink Noise.
Generator / Defaults
Sets the test signal Generator’s level and frequency defaults by using the
arrow buttons to adjust the default values.
To quickly apply a level or frequency default, rather than to adjust it manually,
click on the appropri ate Defaults button. Default levels can be set in 1 dB
steps, from –90 to +10 dB
FS
. The Generator Level cannot be turned off from
the Defaults controls. Default frequencies can be set in 1/12
th
octave steps
from 19.95 Hz to 19.95 kHz.
Tip
By default, the Test Signal Generator is patched to GEN (the third channel
input) of all channels. It also appears as a signal source in the General Patch
and can be patched from there to any desired target.
4.6.4.2
Option: TC Reader / Generator
The TC Reader / Generator page is used for adjusting various settings of the
integrated TC reader and generator, such as the time source and frame rate.
Summary of Contents for Vista 5 M3
Page 18: ...Vista 5 M3 Digital Mixing System 1 2 Introduction Document generated 28 08 13 SW V4 9 ...
Page 40: ...Vista 5 M3 Digital Mixing System 1 24 Introduction Document generated 28 08 13 SW V4 9 ...
Page 90: ...Vista 5 M3 Digital Mixing System 3 2 Parameters Document generated 28 08 13 SW V4 9 ...
Page 144: ...Vista 5 M3 Digital Mixing System 3 56 Parameters Document generated 28 08 13 SW V4 9 ...
Page 300: ...Vista 5 M3 Digital Mixing System 5 4 AutoTouchPlus Document generated 28 08 13 SW V4 9 ...
Page 348: ...Vista 5 M3 Digital Mixing System 5 52 AutoTouchPlus Document generated 28 08 13 SW V4 9 ...
Page 506: ...Vista 5 M3 Digital Mixing System 7 2 DAW Control Document generated 28 08 13 SW V4 9 ...
Page 516: ...Vista 5 M3 Digital Mixing System 7 12 DAW Control Document generated 28 08 13 SW V4 9 ...
Page 518: ...Vista 5 M3 Digital Mixing System 8 2 RELINK Document generated 28 08 13 SW V4 9 ...