background image

STUDER Innotec

 

MBC – User Manual 

 

517/MBC User manual (En–Fr–De–Sp)

 

2 / 2 

Technical specifications 

Parameters 

 

Mains 

1-phase 230 V (100-260 V) 40-60 Hz. At 110 V mains voltage the 
charging current is approximately 40 % of the nominal power. 

Consumption standby on 
mains side 

30 mA (50 mA for the MBC 24-32/1) 

Efficiency 

>85 % (>90 % for the MBC 24-32/1) 

Secondary fuse 

“Car fuse” protection against reverse polarity on connected battery. 

Short circuit proof 

Without blowing the secondary fuse 

Standby consumption on 
battery side 

<2 mA (<0.1 mA for the MBC 24-32/1) 

Mains charging 

Yellow LED lit (14.4/28.8 V). Maximum 20 hours charging time. Switch 
to maintenance charging when current is ~5 % of rated current. 

Floating charging 

Yellow and green LED lit. Battery is fully charged (13.8/27.6 V) 

After mains break 

Charger starts at 14.4/28.8 V, without battery or load the charger starts 
at 13.8/27.6 V 

Protection class 

IP65 (waterproof) 

Safety class 

Class 1 for the MBC 12-15/1; MBC 24-08/1; MBC 24-32/1 
Class 2 (no earth in the mains cable) for the MBC 12-06/1; MBC 24-
03/1 

Operation temperature 

-25 °C to +50 °C 

Temperature protection 

Switches off at 60 °C and starts again at 50 °C 

 

Information 

In accordance with the following EN-norms: 

 

EN60 335-1, EN60 335-2-29, EN 55 014, 55104, EN60 555-2, EN 60555-3. 

 

Swedish SS433077 (Vibration). 

Warning 

Batteries can generate explosive gases – avoid open flames or sparks. It is not allowed 
modifying the mains cable! 