9
8
Wiring
rcm*, remote control module (-rcm models)
enables the AJ remote start up, connector included
• rcm01: Start up when contact closed
• rcm02: Start up when voltage present
• rcm03: Start up when contact open
EN
The device must be installed in accordance with local standards and regulations in force.
FR
L’appareil doit être installé conformément aux normes et réglementations locales en vigueur.
DE
Das Gerät muss gemäß den geltenden örtlichen Normen und Vorschriften installiert werden.
ES
El dispositivo debe instalarse de acuerdo con las normas y regulaciones locales vigentes.
* on request
Battery
cable included (aj 275-400 : 2x2,5mm
2
/ 1,4m) / (aj 500-700 : 2x10mm
2
/ 1,7m)
• black : negative pole (-)
• red : positive pole (+)
Protection device (battery fuse included)
• aj 275-12 : 2 x 30A / aj 350-24 : 2 x 20A / aj 400-48 : 1 x 25A
• aj 500-12 : 3 x 40A / aj 600-24 : 3 x 30A / aj 700-48 : 2 x 30A
M8
AC output
cable included (3x0.75mm
2
/ 1m)
• yellow-green : ground / brown : phase / blue : neutral
L N
solar* PV (s models)
• black : negative pole (-) / red : positive pole (+)
Protection device (solar fuse included)
• 10A : aj 275-12, aj 350-24, aj 400-48 (80Vdc) /
20A : aj 500-12, aj 600-24 / 25A : aj 700-48
Standby system included at 2W only in s models
Standby
2W (1-20W)