Stübbe MOT C2 Series Original Operating Manual Download Page 3

About this document

1

About this document

This manual:

is part of the equipment

applies to all series referred to

describes safe and proper operation during all operating
phases

1.1

Target groups

Operating company

Responsibilities:

Always keep this manual accessible where the device
is used on the system.

Ensure that employees read and observe this docu-
ment, particularly the safety instructions and warnings,
and the documents which also apply.

Observe any additional country-specific rules and reg-
ulations that relate to the system.

Qualified personnel, fitter

Mechanics qualification:

Qualified employees with additional training for fitting
the respective pipework

Electrical qualification:

Qualified electrician

Transport qualification:

Qualified transport specialist

Responsibility:

Read, observe and follow this manual and the other
applicable documents, especially all safety instructions
and warnings.

1.2

Other applicable documents

To download:

Resistance lists

Resistance of materials used to
chemicals

www.stuebbe.com/pdf_resistance/300051.pdf

To download:

Data sheet

Technical data and conditions of operation

www.stuebbe.com/pdf_datasheets/302346.pdf

To download:

CE declaration of conformity

Conformity with standards

www.stuebbe.com/pdf_DOC/302358.pdf

Tab. 1

Other application documents, purpose
and where found

1.3

Warnings and symbols

Symbol

Meaning

Immediate acute risk

Death, serious bodily harm

Potentially acute risk

Death, serious bodily harm

Potentially hazardous situation

Minor injury

Potentially hazardous situation

Material damage

Safety warning sign

Take note of all information
highlighted by the safety warning
sign and follow the instructions to
avoid injury or death.

Instruction

1., 2., ...

Multiple-step instructions

Precondition

Cross reference
Information, notes

Tab. 2

Warnings and symbols

302 352

BA-2020.11.16 US

MOT C2

3

Summary of Contents for MOT C2 Series

Page 1: ...020 11 16 US Print No 302 352 TR MA DE Rev001 ST BBE GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact stuebbe com Internet www stuebbe co...

Page 2: ...3 Storage 6 4 4 Disposal 6 5 Installation and connection 7 5 1 Check operating conditions 7 5 2 Prepare tank 7 5 3 Install device 7 5 4 Electrical connection of device 7 6 Operation 8 6 1 Configure d...

Page 3: ...and the other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents To download Resistance lists Resistance of materials used to chemicals www stuebbe co...

Page 4: ...otective equipment available Qualified personnel Make sure all personnel tasked with work on the device have read and understood this manual and all other appli cable documents especially the safety m...

Page 5: ...t output 3 2 Description The device measures the filling level of a liquid medium with the help of a magnetic float The device transmits the measured value via a standardized 4 20 mA current output 3...

Page 6: ...age due to inappropriate storage Store the device properly 1 Make sure the storage room meets the following condi tions Dry Frost free Vibration free Not in direct sunlight Storage temperature 10 C to...

Page 7: ...ar filling pipes When installing in open tanks or basins do not install the unit over turbulence or the vortex caused by agita tors 5 3 Install device Tank has been properly prepared Avoidance of medi...

Page 8: ...ted properly with the power supply and ready for operation Device is set manually as required For this purpose the current output for filling level must be displayed in the higher level controller as...

Page 9: ...rotective equipment when carrying out any work on the device Error Possible cause Corrective action Float is stuck Clean sensor No change to the output signal Sensor defective Inform ST BBE customer s...

Page 10: ...al data dimensions and accessories are described in the data sheet 1 2 Other applicable documents Page 3 9 2 Plug assignment 2 1 3 4 Fig 3 Connection diagram 1 4 20 mA signal 2 Not assigned 3 Not assi...

Reviews: