Summary of Contents for CC130

Page 1: ...KER MODELS CC130 CC270 CC450 CC900 CC1800 INSTALLATION AND SERVICE MANUAL Revision 6 STUART MANUFACTURING 1 Jayelem Crescent Padstow NSW 2211 Australia Telephone 02 9773 3711 Fax 02 9773 4400 www stum...

Page 2: ...TENTS PAGE Specifications 1 Installation Instructions 2 Adjustments 3 Operation of Machine 4 5 Trouble Shooting 6 8 Logic Board Flow Chart 9 10 Main Circuit Function Diagram 11 Wiring Diagrams 12 18 P...

Page 3: ...0kpa WATER CONNECTION REQUIREMENTS All Models 3 4 BSP male stop cock DRAINAGE All Models 25mm diameter PVC 1 CC130 CC270 CC450 CC900 CC1800 ELECTRICAL REFRIGERATION SUCTION PRESSURE 21deg C FLOODED EV...

Page 4: ...or waste START UP PROCEDURE 1 ENSURE MACHINE IS LEVEL 2 Connect water hose and turn on water 3 Remove front and side panels 4 Turn on power 5 Wait for about 10 seconds then press and hold RESET button...

Page 5: ...ew to increase or decrease as indicated ICE THICKNESS The correct weight of ice per cycle has been factory set with the machine LEVEL If the machine is not installed level this can alter the weight si...

Page 6: ...ect the machine from damage in the event of a power failure during the freezing cycle By using the WARM UP defrost CYCLE when power is restored any ice which had formed on the icemaking plates before...

Page 7: ...cycle Press the CLEAN button the compressor stops and leaves the water pump running Allow cleaner mixture to circulate until the icemaking plates are clean When the icemaking plates are clean remove...

Page 8: ...ESET button 6 The selected diagnostic value is displayed on the numeric display 7 To cancel the diagnostic function press the RESET button again CHECKING OPERATION OF REED SWITCHES The curtain flap sw...

Page 9: ...hine The correct replacement fuse is a slow blow HRC Ceramic Refer parts list for correct size DO NOT USE GLASS TYPE FUSES When changing circuit boards ensure that a The incoming active goes to the re...

Page 10: ...rotating 180 degrees ERROR 4 DID NOT MAKE ICE IN TIME 40 Minutes 1 Partial loss of refrigerant 2 Faulty fan motor 3 Dirty condenser 4 Faulty compressor 5 Hot gas solenoid stuck open 6 Restricted capi...

Page 11: ...S CLEAN BUTTON YES HAS ICE MAKE TIMER TIMED OUT YES HAS THE CORRECT AMOUNT OF WATER BEEN USED TO MAKE ICE YES SET DEFROST PUMP OFF HOT GAS SOLENOID ON BOTH FLAP SWITCHES OPERATED YES DID BOTH FLAPS CL...

Page 12: ...IME COMPRESSOR FILL AND PUMP OFF DISPLAY ERROR CODE 3 RE TRY EVERY HOUR DID THE TROUGH FILL RETURNTO ICE MAKE CYCLE YES NO RESET BUTTONPUSHED NO YES DID NOT MAKE ICE IN TIME DID NOT DEFROST IN TIME CO...

Page 13: ...11...

Page 14: ...12...

Page 15: ...13...

Page 16: ...14...

Page 17: ...15...

Page 18: ...16...

Page 19: ...17...

Page 20: ...18...

Page 21: ...8 050326 050023 050347 1 4mm 2625mm 050009 050010 050011 050043 050065 050043 050045 050046 CC270 050383 050348 050326 050023 050347 1 78mm 2500mm 050009 050010 050011 050043 050065 050043 050045 0500...

Page 22: ...y failure or plumbing problems to the Product for any reason external drain line malfunction adverse operating conditions as set forth in the owner user manual for the Product All claims for labour or...

Page 23: ...only warranties made in connection with the sale and distribution of the Products ANY AND ALL OTHER EXPRESSED STATUTORY AND IMPLIED WARRANTIES APPLICABLE TO THE PRODUCT INCLUDING WITHOUT LIMITATIONS...

Page 24: ...properly iden tify the nature of the failure 5 The labour warranty includes standard straight time charges at the installation location only and does not include charges for travelling time mileage or...

Page 25: ...ll be covered on a pro rata basis up to the warranty expiration of equipment in which they are installed b Warranty on spare parts other than the above is three 3 months from the date of installation...