- 13 -
Cont ...
7 TECHNICAL
SPECIFICATION
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
*Note:
The maximum pressure that can be applied to the pump under any
installation
conditions.
**Note: A stored water temperature of 60°C is considered sufficient to meet all
normal requirements and will minimize deposition of scale in hard water
areas.
7.11
Noise:
The equivalent continuous A-weighted sound pressure level at a
distance of 1 metre from the pump does not exceed 70 dB(A).
Pump Model
S1.4 bar Single
46387
General
Guarantee
3 years
WRAS approval
0304065
Features
Pump type
Centrifugal
Mechanical seal
Nitrile/Carbon/Silicon Carbide
Anti-vibration feet
Inlet strainer(s)
Flexible hoses
2
Dry run protection
Performance
Maximum head (closed valve)
1.4 bar
Performance @ 45 l/min
1.2 bar
Performance @ 90 l/min
0.7 bar
Maximum flow
120 l/min
Maximum static inlet pressure
10 metres
Maximum working pressure*
500 kPa (5 bar)
Maximum ambient air temperature
40
o
C
Min / Max water temperature**
Min 4
o
C / Max 65
o
C
Flow switch sensitivity (approx)
1.0 l/min
Connections
Pump connections
G 1 male
Flexible hoses
Connections
G 1 male x G1 female x 300 mm long
Motor
Type
Induction type, thermally protected
Duty rating
Continuous S1
Electrical
Power supply / phase / frequency
230 V a.c. / 1 / 50 Hz
Current (full load)
2.0 Amps
Power consumption
445 Watts
Fuse rating
5 Amps
Power lead (pre-wired)
1.5 metres
Physical
Enclosure protection
IPX4
Length
273 mm
Width
133 mm
Height (excluding hoses)
264 mm
Weight (including fittings)
7.7 Kg