- 11 -
Cont ...
4.13
Wall plate fixing:
1. If installing the SPU Midi on a wall ensure suitable fixings for the wall
structure are used and are suitable to support the unit when fully
filled with water (see technical section for filled weights). The holes in the
wall plate are 6 mm in diameter, the maximum permissible screw head
height is 3 mm.
2. All holes in the wall mounting plate must have fixings used in them as per
the image below, do not leave out fastenings as this will compromise the
integrity of the wall plate.
3. Ensure you have sufficent room around the area you are mounting the SPU
Midi to allow installation, servicing and operation. See section 2.12.
4. Ensure wall plate is fixed to a flat vertical wall and the top of the plate is
horizontal.
5. Retain the SPU Midi to the wall mounting plate using the single M6
retaining screw at the top of the wall plate.
6. Fit the plastic cover by pressing as indicated below with the palm of the
hand as until the Dual Lock
TM
is heard to ‘click’.
Fig. 7
Fig. 8
Fig. 9
Summary of Contents for 46721