edges. Check the device and the power-cord from time to time. If extension cords are used, make sure 
that the core diameter is sufficient for the required power consumption of the device. All warnings 
concerning the power cords are also valid for possible extension cords.   
 

 

OPERATING DETERMINATIONS 

 

This device is designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. Do not shake the device. Avoid brute force when 
installing or operation the device. Never lift the fixture by holding it at the projector-head. As the 
mechanics may be damaged. When choosing the installation-spot, please make sure that the device is 
not exposed to extreme heat, moisture or dust. There should not be any cable lying around. Please 
make sure that the fixture can not be touched or bumped. Your endanger your own and the safety of 
others.   
 
device are forbidden due to safety reasons! Never remove the serial barcode from the device as this 
would make the guarantee void. If this device will be operated in any way different to the one described 
in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any 
other operation may lead to dangers like short-circuit, burns, electric shock, crash etc.   

 

DESCRIPTION OF THE DEVICE 

 

Features 

> 11 channel DMX-512 .in optional 
> Variable electronic strobe. 
> Variable electronic dimmer (0-100%).and 4 type in optional 
> LED operation menu with function buttons   
> Reset to factory settings option. Color temperature setting 
> Build-in program with speed adjustment 
> 16 bit dimmer effect and White balance   
> Temperature sensor via software to control fans speed against overheat 
> 6 different DMX channel mode. Including STAG, ARC1,AR1D,ARC2,AR2D,AR2S and HSV   
 

INSTALLATION   
 
Rigging   
The installation of the projector has to be built and constructed in a way that it can hold 10 times the 
weight for 1 hour without any harming deformation. 
 
IMPORTANT!OVERHEAD  RIGGING  REQUIRES  EXTENSIVE  EXPERIENCE,  including  calculating 
working  load  limits,  installation  material  being  used,  and  periodic  safety  inspection  of  all  installation 
material and the projector. If you lack these qualifications, do not attempt the installation yourself, but 
instead  use  a  professional  structural  rigger.  Improper  installation  can  result  in  bodily  injury  and  or 
damage to property. The projector had to be installed out of the reach of people 
 
DANGER  OF  FIRE!  When  installing  the  device,  make  sure  there  is  no  highly-inflammable 

Summary of Contents for COB PAR 100SQ WASH

Page 1: ...COB PAR 100SQ WASH User Manual Ver1 0 ...

Page 2: ...INSTRUCTIONS 2 OPERATING DETERMINATIONS 3 DESCRIPTION OF THE DEVICE 4 INSTALLATION 5 OPERATION 6 Stand alone operation 6 Master slave operation 6 DMX controlled operation 6 Addressing 6 Control board 6 DMX protocol 7 TECHNICAL SPECIFICATIONS 7 ...

Page 3: ...come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never touch them with wet hands as this could lead to mortal electrical shock Never modify bend strain mechanically put pressure on pull or heat up the power cord Never operate next to sources of heat or cold Disregard can lead to power cord damages fire or mortal electrical shock T...

Page 4: ...s and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock crash etc DESCRIPTION OF THE DEVICE Features 11 channel DMX 512 in optional Variable electronic strobe Variable electronic dimmer 0 100 and 4 type in optional LED operation menu with function buttons Reset to factory settings option Color temperature setting Build in program...

Page 5: ...EC standards OPERATION After you connected the effect to the mains The fixture starts running Stand Alone operation In the stand alone mode the fixture can be use without controller Master slave operation The master slave operation enables that several devices can be synchronized and controlled by one master device DMX controlled operation You can control the projectors individually via your DMX c...

Page 6: ...lection DMX Adjust DMX value from 001 to 512 PERS STAG Run static mode 11channel with details on dmx protocol ARC 1 Run 3 channel mode Red Green Blue warm white AR1 d Run 4 channel mode Dimmer Red Green Blue warm white ARC 2 Run 4 channel mode Red Green Blue warm white AR2 d Run 5 channel mode Dimmer Red Green Blue warm white AR2 5 Run 6 channel mode Dimmer Red Green Blue warm white Strobe HSV Adj...

Page 7: ...ary to use a terminator at the last fixture DMX protocol Channel Value Function 1 0 255 Dimmer 0 100 dimmer 2 0 255 Red 0 100 Red 3 0 255 Green 0 100 Green 4 0 255 Blue 0 100 Blue 5 0 255 Warm white 0 100 Warm white 6 0 5 6 20 21 30 31 50 51 70 71 90 91 110 111 130 131 150 151 170 171 190 191 200 201 255 Color Change No function Color change No function R 100 G 0 100 B 0 W 0 R 100 0 G 100 B 0 W 0 ...

Page 8: ...ional 1st channel Dimmer be open Dimmer speed No function Dimmer 1 Dimmer 2 Dimmer 3 Dimmer 4 11 0 9 10 211 211 222 ID selection After select the fixture per ID1 ID66 control via DMX when open value as below per each model even they are at same dmx value No function Each 10 value with a ID from ID1 until ID19 Each value with a ID from ID20 until ID66 TECHNICIAL SPECIFICATIONS Model COB PAR 100SQ W...