background image

7

Cable Cover

Installing the Cable Cover

1. 

Align the left and right hinges of the cable cover onto the bottom rear of the display.

2. 

Snap on the top section of the cable cover to the aligning clips.

3. 

With your fi ngers, turn the thumbscrews clockwise to tighten and lock the cable cover 

onto the display.

Removing the Cable Cover

1. 

With your fi ngers, turn the thumbscrews counterclockwise to loosen.

2. 

Once the thumbscrews are completely loosened, pinch the left and right clips and pull the 

cable cover towards you.

3. 

Remove the cable cover from the left and right hinges.

Summary of Contents for VisionPro

Page 1: ...VisionPro 26 LED Display 0240 031 020 ...

Page 2: ...Use 3 Indications 3 Contraindications 3 Package Contents 4 Device Features 5 Setup 9 Connections 9 Basic Video Setup 11 Operation 12 On Screen Display OSD 12 OSD Menus 14 Troubleshooting 16 Cleaning and Maintenance 17 Technical Specifications 18 Symbols and Definitions 22 ...

Page 3: ...used adjacent to or stacked with other devices If adjacent or stacked use is necessary the device should be observed to verify normal operation in the configuration in which it will be used 8 Test this device prior to a surgical procedure This device was fully tested at the factory before shipment 9 Do not attempt internal repairs or adjustments not specifically detailed in this manual Ensure that...

Page 4: ...ed of as unsorted municipal waste and must be collected separately For a Class B digital device or peripheral the instructions furnished the user shall include the following or similar statement placed in a prominent location in the text of the manual NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limi...

Page 5: ...Display is intended for video display during surgical procedures Indications This device is indicated for the following surgical procedures Arthroscopy orthopedic surgery Laparoscopy general and gynecological surgery Thorascopy Endoscopy general gastroenterological and ENT ENT Gynecology General surgery The display is a non sterile reusable device not intended for use in the sterile field The disp...

Page 6: ...ionPro 26 LED Display 2 4 M4 16 mm VESA screws 3 Hospital grade AC power cord 4 0240 031 004 Medical Power Supply 5 Cable Cover Part Number Optional Accessories 0240 031 002 VisionPro 26 Display Cover 0240 030 951 15 ft 5 pin DC extension cable 0240 030 952 75 ft 5 pin DC extension cable ...

Page 7: ...o image 3 Power switch soft Powers the display ON and OFF 4 Power LED Indicates current status Shines green if the display is powered on or is in screen saver mode blinks red if the display is in sleep mode blinks amber if over or under voltage 5 PIP Accesses the Picture in Picture adjustment menu 6 Bright Accesses the Brightness adjustment menu 7 Specialty Accesses the Specialty adjustment menu 8...

Page 8: ...handles are not intended to bear the entire weight of the display 6 Cable cover hinges Attach the bottom of the cable cover to the display 7 Velcro straps Straps aid in cable management 8 Cable cover thumbscrews Attach the cable cover to the display and are tightened or loosened using fingers 9 Cable cover Covers and conceals cables 10 Cable cover clips Attach the top of the cable cover to the dis...

Page 9: ... aligning clips 3 With your fingers turn the thumbscrews clockwise to tighten and lock the cable cover onto the display Removing the Cable Cover 1 With your fingers turn the thumbscrews counterclockwise to loosen 2 Once the thumbscrews are completely loosened pinch the left and right clips and pull the cable cover towards you 3 Remove the cable cover from the left and right hinges ...

Page 10: ...r the full weight of the display Removing or Reinstalling the Display Handles To Remove 1 Using a 3mm hex key loosen the two M4 x 30mm screws and gently pull the handle away from the display To Reinstall 1 Align the handle with the screw holes on the rear of the display 2 Using a 3mm hex key install the two M4 x 30mm screws to attach the handle ...

Page 11: ...t you and your staff on its operation and maintenance To schedule an inservice contact your local Stryker Endoscopy representative after your device has arrived Connections Connection Ports Video input signals are connected to the rear of the display as illustrated below 1 2 3 4 5 6 6 6 6 8 7 6 6 6 9 6 6 6 10 6 6 6 11 6 6 6 12 1 DVI 2 3G HD SD SDI in 3 3G HD SD SDI out 4 VGA 5 S Video 6 C Video SO...

Page 12: ... 2 Connect the AC power cord to the power supply 3 Connect the AC power using the supplied hospital grade power cord 4 Optional not shown Connect an extension cord between the power supply and display 5 Install cable cover Power supply Model Number BPM150S24F11 Manufacturer Bridgepower Corp ...

Page 13: ...11 Basic Video Setup 1 Route the video output 1 from the camera to the SDC DVI input 2 Route the video output 1 from the SDC DVI output to the DVI input on the display ...

Page 14: ...vigate the menus once they are activated 1 PIP Activates Picture Mode Picture in Picture Picture by Picture Picture on Picture 2 Bright Activates the Brightness adjustment menu 3 Specialty Activates the Specialty adjustment menu 4 Input Activates the Input selection menu To use the Rotary Control Push Accesses selects on screen display menu Turn Right Left With the on screen display menu activated...

Page 15: ...ress the Rotary Control to enter the next level OSD 4 Rotate the Rotary Control to increase or decrease the value of the selected parameter or to make a selection on different options 5 To exit the OSD menu screen from the second or third level OSD menu select the Exit option To completely exit the OSD press and hold the Rotary Control If no keys are pressed the OSD will automatically exit after t...

Page 16: ...eases or decreases the contrast 0 100 Phase Increases or decreases the Phase level 0 100 Chroma Increases or decreases the Chroma level 0 100 Image Sharpness Sets image sharpness 1 10 Video Sharpness Increases or decreases the video sharpness 0 100 Only available under SDI S or C video input Image Effect Menu Item Description Scale Mode Chooses scale mode between Fill All V Fill H Fill One To One ...

Page 17: ...isplay Menu Position Background and Timeout Restore Factory Settings Sets to factory default Screen Control VGA Horizontal Vertical Phase Frequency S Video C Video SOG RGBs Component Horizontal Vertical Information Menu Item Description User Name Entry Enters custom user name display for boot up display Serial Number Displays device serial number Runtime Displays current device total run time Inpu...

Page 18: ...linking Red Display is in sleep mode Press any key to wake the display Amber The power supply may be over or under voltage Abnormal picture Oversized undersized or missing video or center shift Using the Screen Control Menu adjust the Phase Frequency Horizontal and Vertical settings in order to correct the display image Adjust settings in Scale Mode For VGA input only push and hold the rotary cont...

Page 19: ... Should the unit need cleaning 1 If the display cover is in place remove the cover prior to cleaning 2 Apply standard disinfectant or mild detergent to a dry sterile cloth 3 Wipe the unit 4 Take extra care when cleaning the screen Excess liquid or drips that enter the bottom of the screen may result in product damage Disposal This product contains electrical waste or electronic equipment It must n...

Page 20: ...applicable local regulations and standards 110V 10V power outlets Select a power supply cord that is UL Listed and C S A ed type SJT or SVT 3 conductor 18AWG terminated in a molded on hospital grade plug cap rated 220V 20V power outlets Select a power supply cord that is internationally harmonized and marked HAR 3 conductor 0 75 be suitable for medical use Dimensions Dimensions W H D VESA Mounting...

Page 21: ... minimize total leakage current per patient ensure that all systems are installed according to the requirements of IEC 60601 1 1 Caution ect the normal function of the display Do not use cables or accessories other than those provided with the display as this may result in increased electromagnetic emissions or decreased immunity to such emissions If the display is used adjacent to or stacked with...

Page 22: ...covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burst IEC61000 4 4 2kV for power supply lines 1kV for input output lines 2kV line to ground 1kV line to line Mains power quality should be that of a typical commercial or hospital environment Surge IEC61000 4 5 1kV differential mode 2kV common mode 1kV differential mode 2kV common mode Mains power...

Page 23: ...to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the VisionPro 26 LED Display is used exceeds the applicable RF compliance level above the display and transmitter should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating ...

Page 24: ...nufacturer Tested to comply with FCC Class B standards Federal law restricts this device to sale by or on the order of a physician Complies with the requirements of directive 93 42 EEC This p Medical Equipment is in accordance with UL 60601 1 and CAN CSA C22 2 No 601 in regards to electric shock fire hazards and mechanical hazards roduct contains electrical waste or electronic equipment It must no...

Page 25: ...23 ...

Page 26: ...900 Optical Court San Jose CA 95138 USA 1 408 754 2000 1 800 624 4422 www stryker com European Representative Regulatory Manager Stryker France ZAC Satolas Green Pusignan Av De Satolas Green 69881 MEYZIEU Cedex France P22286A 2013 02 ...