Frequency adjustment

 

 

Enter testing mode

Hold COLOR to power on

adjust FREQ for rough adjust

CLAR external spindle for fine adjust

FUNC

COLOR key are used to switch between testing items. 

 

VCO frequency adjustment

  Testing point TP513

  FM mode

CLAR inner spindle in middle position

an Obviously fixed-point 

can be find in middle point

before adjustment, power on radio in USB mode for 2-5 minutes. 

             

Choose FRQ

 

320

adjust L807

frequency 38.695MHZ

±

10HZ

background    noise < 40HZ 

Choose F05

 

XXX

adjust frequency 38.695MHZ

±

10HZ

background noise < 40HZ 

Turn clockwise and anti clockwise to the end and test.    the fluctuation need 500

±

100Hz, switch the knob 

to middle position after testing. 

             

Choose F15

 

XXX

  frequency need 38.695MHZ

±

10HZ

background noise < 40HZ 

Turn clockwise and anti clockwise to the end and test. the fluctuation need 1500

±

200Hz, switch the knob 

to middle position after testing. 

Choose F25

 

XXX

  frequency need 38.695MHZ

±

10HZ

background noise < 40HZ 

Turn clockwise and anti clockwise to the end and test. the fluctuation need 2500

±

300Hz, switch the knob 

to middle position after testing. 

Note

FRQ

 

320 data can not adjusted

if the frequency fluctuation is <100HZ

you can adjust 

±70> 

After    testing FO5

F15

F25 frequency fluctuation

be sure to turn the CLAR inner spindle in middle position. 

 

BFO frequency adjustment

Enter testing mode

choose BFXX display

testing point TP301 

Choose FM mode

frequency need 10.695MHZ

±

10HZ

background noise < 40HZ 

Choose USB mode

frequency need 10.6975MHZ

±

10HZ

background noise < 40HZ 

Choose LSB mode

frequency need 10.6925MHZ

±

10HZ

background noise < 40HZ 

 

AFF frequency adjustment

Enter testing mode

choose AFFXXX display

testing point TP514 

                Choose FM mode

frequency need 10.240MHZ

±

40HZ

background noise < 40HZ 

 
Note1

During alignment

choose the minimum deviated frequency, do well adjust and warm up the testing machine. 

If the deviation not meet standard, revise the C582    5P capacitance

Capacitance between 1-6P

if still not OK

check 

other index. 

Note2

T he final frequency are composed by BFO and VCO frequency, when the testing transmitting frequency is error, it is 

necessary  to  recheck  both frequency.  Due  to  high requirement  on  accuracy, do  adjust  this  2  frequency  after  the 
temperature  turn  normal  if  any  soldering  work  near  the  10.24MHZ,  and  10.6975  MHz  component.  Y800,  Y501, 
Y500  must  grounded,  the  housing  of  L807  and  Y800  shall  be  touched.  After  finish  above  alignment,  be  sure  to 
install the shield over the 2 VCO to ensure rest alignment 

。。。

。。。

。。。

 

 

TX testing 

。。。

。。。

。。。

 

Note

Voltage 13.8V

testing machine with filter

20HZ

 

HPF and 15KHZ

 

LPF

DE

EMPHASIS is OFF

Clockwise turning 

is for increase power, anti clockwise turning is for reduce low. The power switch only work for AM,FM mode. 

If the power is too big, connect a Attenuator with testing machine.   

。。

。。。

。。。

。。。

 

TX Voltage

When the FM power is over 50W

时(

current around 9A

The voltage is 13V 

Switch  location

  All  the  5 Rocker  Switch  fix in middle position

CLAR  inner  spindle  fix in  middle  point 

MIC

 

GAIN  to 

maximum 

Summary of Contents for SR-955HP

Page 1: ... show RED GREEN BLUE 3 colors make sure the LED work fine before install LCD board B Switch to DIM position The big LCD show DIM 31 adjust channel knob until big LCD show DIM OFF check the changes of darkles the smaller data get darker backlight Check voltage In function menu the LCD xxx Set to N DC the big LCD show voltage The voltage shall be 0 10Vcomapred with the supplied voltage adjust the R5...

Page 2: ... mode frequency need 10 695MHZ 10HZ background noise 40HZ Choose USB mode frequency need 10 6975MHZ 10HZ background noise 40HZ Choose LSB mode frequency need 10 6925MHZ 10HZ background noise 40HZ AFF frequency adjustment Enter testing mode choose AFFXXX display testing point TP514 Choose FM mode frequency need 10 240MHZ 40HZ background noise 40HZ Note1 During alignment choose the minimum deviated ...

Page 3: ...2 send 2K 30 mV signal to MIC MIC GAIN adjust to maximum then adjust W500 to get frequency deviation between 3 5 0 2KHZ the deviation on channel 1 3 shall between 3 4 0 KHZ FM transmitting background noise Choose channel 1 2 3 adjust output power to maximum MIC short circuited the background noise shall 50HZ Power RSSI meter Choose channel 2 1 2 bar for minimum power Display 40 60 for 50W SWR Choo...

Page 4: ...2 1 1 5K 2 1 2K 2 1 2 50K 2 1 3K 6 1 4K 18 13 5K 26 20 AM low Power residual amplitude modulation Choose channel 1 2 3 adjust to minimum power send 1K 30 mV signal to MIC when testing machine on FM residual amplitude modulation need 1 2KHZ AM High power residual amplitude modulation Choose channel 1 2 3 adjust to maximum power send 1K 30 mV signal to MIC when testing machine on FM residual amplitu...

Page 5: ...ND 11db testing machine set on 121db frequency add 1k on main frequency modulation off LSB sensitivity choose channel 1 2 3 SP output margin shall 1 0V SIND 11db testing machine set on 121db frequency add 1k on main frequency modulation off RSSI meter Choose channel 2 adjust W5 to let RSSI 67dBm the meter just in S9 position in channel 1 2 3 when RSSI 5dBm the meter shall full bar and on 110dBm di...

Page 6: ...y choose channel 2 SP output margin between 2 3V the SIND on channel 1 2 3shall 11dB testing machine set on 119dBm 1K 1 2K SP maximum output margin choose channel2 when the SP is maximum the margin shall be 4 7V 5 3V current 0 8A then adjust SP to 2 3V the SIND shall 33dB SNR 35dB testing machine set on 47dBm 1K 1 2k AF sensitivity choose channel 2 when the SP is maximum the margin shall between 3...

Reviews: