Reprocessed by 

 
 

 

 
 

Instructions for Use 

Reprocessed Ultrasonic Focus™ Curved Shears 

 
 

 
 

Reprocessed Device for Single Use

 

 

Caution: 

Federal (U.S.A.) law restricts this device to sale by or on the order of a 

physician. 

 

 

STERILE 

 
 

Explanation of Icons 

 

 

Sterilized by Ethylene Oxide Gas 
 

 

Date of Reprocessing 
 

 

Use by Date 

 

Product Code 

 

Do Not Reuse 

 

See Instructions For Use 

 
 

Stryker Sustainability Solutions, Inc.  © 2006, 2011 
Phoenix, AZ 85044  

sustainability.stryker.com

 

888.888.3433  

Summary of Contents for Reprocessed Ultrasonic Focus

Page 1: ...ral U S A law restricts this device to sale by or on the order of a physician STERILE Explanation of Icons Sterilized by Ethylene Oxide Gas Date of Reprocessing Use by Date Product Code Do Not Reuse See Instructions For Use Stryker Sustainability Solutions Inc 2006 2011 Phoenix AZ 85044 sustainability stryker com 888 888 3433 ...

Page 2: ... hazards consult the medical literature Prior to the initiation of the procedure verify compatibility of minimally invasive instruments and accessories when they will be used together since there may be variations from manufacturer to manufacturer The use of these instruments requires a thorough understanding of the techniques and principles of laser electrosurgical and ultrasonic procedures Inapp...

Page 3: ...ect the instrument for overall condition and physical integrity Do not use the instrument if any damage is noted Return the instrument and packaging to Stryker Sustainability Solutions if it is not in acceptable condition for surgery 4 Attach the Blue Grip Assist on the Hand Piece to the instrument by rotating the instrument onto the Hand Piece in a clock wise rotation as viewed from the distal en...

Page 4: ... power level is activated by pressing the right foot pedal of the footswitch or distal hand control button MAX 11 Note Premature blade failure could occur from scratches on the blade a When instrument is in use avoid accidental contact with other instruments b Use only the Torque Wrench to attach or detach the instrument from the hand piece 12 Close the clamp arm by closing the finger rings togeth...

Page 5: ...al numbers or other identification marks have been removed or destroyed If Stryker determines in its reasonable discretion that the claimed defect or non conformance in the product is excluded from warranty coverage as described hereunder it will notify the customer of such determination TO THE FULLEST EXTENT PERMITTED BY LAW THE EXPRESS WARRANTY SET FORTH HEREIN IS THE ONLY WARRANTY APPLICABLE TO...

Reviews: