4. Press and hold both A
Arrm
m//D
Diissa
arrm
m and W
We
eiig
gh
h together for 6 seconds until sse
ett appears on the display to save your
selected pattern.
5. Release A
Arrm
m//D
Diissa
arrm
m and W
We
eiig
gh
h.
N
No
otte
e -- The pattern setting you selected appears on the display. A brief sample of the pattern confirms your pattern
setting.
S
Se
ettttiin
ng
g tth
he
e C
Ch
ha
ap
pe
erro
on
ne
e o
op
pttiio
on
n a
alle
errtt vvo
ollu
um
me
e
To change the C
Ch
ha
ap
pe
erro
on
ne
e option alert volume:
1. Press and hold both Z
Ze
erro
o and llb
b//kkg
g together until vvo
oll appears on the display (
Scale icon/button identification
29)).
2. Release Z
Ze
erro
o and llb
b//kkg
g.
N
No
otte
e -- The volume levels L
L ((1
1--4
4)) appear on the display.
3. Press Z
Ze
erro
o or llb
b//kkg
g to scroll through the volume levels.
N
No
otte
e -- A brief sample of the volume plays as you scroll through the volume levels.
4. Press and hold both Z
Ze
erro
o and llb
b//kkg
g together for 6 seconds until sse
ett appears on the display to save your selected
volume level.
5. Release Z
Ze
erro
o and llb
b//kkg
g.
N
No
otte
e -- The volume level you selected appears on the display. A brief sample of the volume level confirms your volume
level setting.
C
Ch
ha
arrg
giin
ng
g tth
he
e sscca
alle
e ssyysstte
em
m b
ba
atttte
erryy p
pa
acckk o
op
pttiio
on
n -- e
elle
eccttrriicc lliitttte
err o
op
pttiio
on
n o
orr e
elle
eccttrriicc lliitttte
err o
op
pttiio
on
n w
wiitth
h
C
Ch
ha
ap
pe
erro
on
ne
e o
op
pttiio
on
n -- P
Prriim
me
e o
on
nllyy
The scale system with the electric litter option requires one 10.8V Li-ION battery pack (0058-135-000 without the
C
Ch
ha
ap
pe
erro
on
ne
e option; 0058-134-000 with the C
Ch
ha
ap
pe
erro
on
ne
e option). Recharge the battery pack when the battery charge
indicator displays one unit remaining. This prevents the scale system option from shutting down due to drained batteries.
To recharge the scale system Li-ION battery pack, plug the power cord into a grounded, hospital grade wall outlet. The
battery pack fully charges in approximately three hours.
N
No
otte
e -- Always plug the product into a grounded, hospital grade wall outlet when not in use. This helps the battery to
maintain a sufficient charge and maximizes product performance while on battery power.
R
Re
ep
plla
acciin
ng
g tth
he
e b
ba
atttte
erriie
ess ffo
orr tth
he
e sscca
alle
e ssyysstte
em
m o
op
pttiio
on
n -- n
no
on
n--e
elle
eccttrriicc lliitttte
err
Replace the batteries when the battery charge indicator displays one unit remaining. This prevents the scale system option
from shutting down due to drained batteries.
When the display flashes L
Lo
o b
ba
atttt, the batteries are at their lowest charge and the scale system option is disabled.
T
To
oo
ollss rre
eq
qu
uiirre
ed
d::
•
Phillips screwdriver
•
Four AA batteries (Alkaline type (LR6))
To replace the batteries:
1. Using a Phillips screwdriver, the screws that hold the battery compartment cover to the display assembly.
2. Remove and discard all four AA batteries.
N
No
otte
e -- Always dispose of old batteries in accordance with local regulations.
3. Place four new AA batteries as indicated in the battery holder.
N
No
otte
e -- Never mix old batteries with new batteries.
1115-309-001 Rev C.2
31
EN
Summary of Contents for Prime 1105
Page 2: ......
Page 64: ...1 10 00 08 8 0 01 10 0 3 30 02 2 Rev U A A 1008 015 820 1 EN 60 1115 309 001 Rev C 2 ...
Page 66: ...1 10 00 08 8 0 01 15 5 0 02 20 0 Rev B A A 1008 015 800 1 EN 62 1115 309 001 Rev C 2 ...
Page 68: ...1 10 07 70 0 0 01 10 0 1 10 00 0 Rev J A A 1008 037 810 1 EN 64 1115 309 001 Rev C 2 ...
Page 70: ...1 10 07 70 0 0 01 10 0 2 20 00 0 Rev J A A 1008 037 800 1 EN 66 1115 309 001 Rev C 2 ...
Page 71: ...1 10 01 18 8 0 01 15 5 3 30 05 5 Rev K A A 1008 002 800 1 1115 309 001 Rev C 2 67 EN ...
Page 72: ...1 10 01 18 8 0 01 15 5 4 40 05 5 Rev L A A 1008 002 810 1 EN 68 1115 309 001 Rev C 2 ...
Page 73: ......