Instructions for Use
nGenius Universal Tracker
REF 6000-014-000
2007-11-21
6000-014-700 Rev. B
www.stryker.com
CPT Use Only
C
Page 1: ...Instructions for Use nGenius Universal Tracker REF 6000 014 000 2007 11 21 6000 014 700 Rev B www stryker com CPT Use Only C ...
Page 2: ... service is re quired contact Stryker Navigation Customer Service Performing procedures with instruments other than those specified in these instructions or out side of their intended use compromises navigati on accuracy 1 Manufactured and Distributed by Stryker Leibinger GmbH Co KG Bötzinger Straße 41 79111 Freiburg Germany t 49 761 4512 0 Distributed by Stryker Navigation 4100 East Milham Avenue...
Page 3: ... do not use the nGenius Universal Tracker Ensure the generic interface pin is fully inserted into the tracker s notch and snaps into position Take special precautions regarding electro magnetic compatibility EMC when using this medical electronic equipment Install and put the equipment into service according to the EMC in formation in the EMC Specifications Manual REF 6000 005 760 This medical equ...
Page 4: ...ersal Tracker LEDs are not facing Navigation System camera Ensure the LEDs are facing Navigation System came ra Retry Instrument tip damaged or bent Replace by another instrument Return the broken instrument for ser vice Incorrect instrument selected Compare the reference number displayed on the monitor with the num ber on the selected instrument Communication with the system fails after Navigatio...
Page 5: ...tion RF ID operating frequency 125 kHz 4 Only use the manual cleaning method Refer to the Guide for Cleaning and Steam Based Sterilization REF 6000 005 750 for cleaning safety and cau tion notes cleaning equipment as well as detailed cleaning and inspection instructions For the nGenius Universal Tracker follow the procedure for Manual Cleaning and Disinfection of Instruments with Electronics as de...
Page 6: ... cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential instal...
Page 7: ... Generic Interface Pin The nGenius Universal Tracker is compatible to devices fitted with generic interface pins with a and without b an RF ID transponder as shown in figure 3 To attach or detach the tracker follow the visual instructions in figure 4 4 Using the nGenius Universal Tracker to Validate Navigated Instruments Initialize both the nGenius Universal Tracker and the navigated instrument Ai...
Page 8: ...nfrared LEDs 9x Status Light Release Button SELECT Button Validation Disc Figure 1 Functional Parts Figure 2 Battery Installation Figure 3 Generic Interface Pins Figure 4 Attaching Tracker to a Device with a Generic Interface Pin Figure 5 Instrument Validation ...