Stryker Mul-T-Pad 8002-062-612 Operation Manual Download Page 2

This manual assists you with the operation of the Stryker Model 8002-062-
612, 8002-062-622, and 8002-062-626 

Mul-T-Pad®

. Read this manual before 

operating this product and keep a copy on file.  Set methods and procedures 
to educate and train your staff on the safe operation of this product.

Intended use

The 

T/Pump

® localized therapy system supplies warm or cold water at 

controlled temperatures.  Delivery of the water is through the thermal transfer 
devices (

Mul-T-Pad

) for localized temperature therapy. The 

T/Pump

 is for use 

in situations where physicians determine temperature therapy is necessary 
or desired.

Localized temperature therapy is of particular benefit in treating the following: 
• 

Orthopedic conditions such as acute injuries, chronic pain, lower back 
pain, muscle spasm, and strains; 

• 

Skin trauma such as abscesses, boils, bruises, burns and contusions; 

• 

Other medical conditions such as chronic arthritis, neuritis, phlebitis, 
tendonitis, and IV infiltration; and symptoms such as infections and 
localized pain.

Product description

The 

Mul-T-Pad 

is a lightweight polymer. The colder style connectors provide 

the means to connect to the temperature controller. The button design allows 
water to flow when the pad is folded to form a customized fit. 

Expected life

These 

Mul-T-Pad 

products have a 30 day single patient use expected life 

upon first use and under normal use conditions.

Contraindications

For heating: 
• 

Application to a body surface with compromised blood flow (Ischemia, 
area under pressure, arterial insufficiency). 

• 

Application to a patient with an increased tendency to bleeding 
(aggravates potential for hemorrhage). 

• 

Application to a body surface with possibility of malignancy (tissue 
metabolism is increased and therefore, the growth potential of the 
malignant tissues). 

• 

Treatment of hematoma within first 24-48 hours (potential for re-bleeding 
and hemorrhage). Recent sprain or fracture (acute inflammatory 
response). 

• 

In combination with topical solutions whose toxicity may be affected by 
the application of heat. 

• 

In combination with other heat sources. 

For cooling:
• 

Application to body surface with compromised blood flow (Ischemia, 
area under pressure, arterial insufficiency

• 

Application to body surface with known vascular impairment such as 
frostbite, arteriosclerosis or ischemia

• 

Application to body surface in people with hypersensitivity to cold, such 
as people with Raynaud’s phenomenon, cold urticaria, cryoglobulinemia, 
and paroxysmal cold hemoglobinuria

• 

Application to body surface in people with impaired sensation

• 

In combination with topical solutions whose toxicity may be affected by 
the application

Specifications

Material

rayon, ethylene vinyl acetate (EVA), polypropylene, 
polyethylene 

Model

8002-062-612

8002-062-622

8002-062-626

Length

18 in.

46 cm

22 in.

56 cm

26 in.

66 cm

Width

13 in.

33 cm

15 in.

38 cm

18 in.

46 cm

Compatible 
controllers

T/Pump

 series temperature controllers

Environmental 

conditions

Operating

Storage and 

transportation

Temperature

90 °F
(32.2 °C)

60 °F

(15.6 °C)

120 °F
(48 °C)

-20 °F

(-29 °C)

Relative humidity

30%

75%

10%

95%

Stryker reserves the right to change specifications without notice.

A

Figure 1: Batch lot code

Assessing the patient’s skin condition
Note:

 Follow your facilities skin care protocol. The following instructions are 

recommendations.
1. 

Document initial skin assessment.

2. 

Check for any foreign items such as medical patches, IV’s, sutures.

3. 

Check for fluids such as moisture or gels.

4. 

Verify the pad size is correct before applying to the patient.

Note

: Apply the pad directly to the skin or add minimal layers.

Connecting the pad (colder style connectors)

1. 

Close the pinch clamps on the connector hose and 
pad (Figure 2).

2. 

Insert the male coupling of pad into the female 
coupling of hose. Press until you hear a click 
(Figure 3).

3. 

With a light pull, make sure that you locked the 
connectors.

4. 

Open all clamps on the connector hose and the 
pad (Figure 4).

5. 

Insert the power cord into a wall outlet. 

6. 

Press the power button to turn on the controller. See 
the controller instructions for use.

7. 

Check that the pad fills with water. 

Note:

 

• 

Iodine based disinfectants will stain the product. Staining does not affect 
the patient nor the use of the product. 

• 

Do not use pins or sharp objects with this product. 

• 

If you fold the pad, place the end of the pad that contains the tubing 
away from the patient.

Rechecking the patient’s skin condition

Check the patient at regular intervals as directed by hospital protocol. Note any 
change in the skin integrity that relates to: 
• 

Excessive moisture - dry the skin surface by wiping away the moisture

• 

Color of the epidermis

• 

Skin texture

• 

Patient’s skin condition is acceptable to continue therapy

Check the pad

Check the pad at regular intervals as directed by hospital protocol.
• 

position

• 

water status

• 

dry surface

• 

leaks

• 

cracks

Defibrillation considerations

1. 

Remove the pad to expose patient’s chest.

2. 

Remove excess moisture.

Disconnecting the pad from the hoses

1. 

Power off the controller. 

2. 

Close pad clamps (Figure 2).

3. 

Press down on the thumb tab of the female coupling. Pull the male 
coupling out to disconnect (Figure 5).

4. 

Discard pad after use per facility protocol. 

Note:

 Do not discard the controller connector hose after use, save for next 

use.

Figure 5: Disconnect

Figure 2: Close

Figure 4: Open

Figure 3: Connect

Operation

Introduction

Introduction

Contact information

Contact Stryker Customer Service at 1-800-327-0770.

Stryker Medical
3800 E. Centre Avenue
Portage, MI 49002  USA

Have the Lot batch code of your Stryker product available when calling 
Stryker Customer Service or Technical Support. Include the Lot batch code 
in all written communication.