11

1.9  BED ILLUSTRATION (Bed may differ from illustration) 

 

 

HEAD IV POLE 

HOLDERS

 

RESTRAINT STRAP 

LOCATIONS

 

HEAD END 

CASING

 

SIDE MATTRESS 

RETAINERS

 

RESTRAINT STRAP 

LOCATIONS

 

EMERGENCY  

CRANK STORED

 

FOLEY BAG HOOKS

 

   FOOT END 

CASING 

 

EMERGENCY 

CRANK  OPENINGS

 

FOOT IV POLE 

HOLDERS

 

SIDE MATTRESS 

RETAINERS

 

FOOT MATTRESS 

RETAINERS

 

PATIENT HELPER 

MOUNTING SOCKETS

 

HEAD BOARD

 

SIDERAIL OUTSIDE 

CONTROL PANEL

 

PUSH

/

PULL HANDLE

 

FOOT BOARD

 

BRAKE

/

STEER 

PEDAL

 

FOOT BOARD 

CONTROL PANEL

 

HEAD SIDERAIL

 

FOOT SIDERAIL

 

SIDERAIL INSIDE 

CONTROL PANEL

 

ON

/

OFF SWITCH

 

HEAD SECTION

 

CENTER SECTION

 

THIGH SECTION

 

FOOT SECTION

 

SIDERAIL LATCH 

LEVER

 

FIFTH WHEEL

 

Figure 1.9 

Summary of Contents for GOBED 2500

Page 1: ...da E Mail Canada service bertec strykercorp com Manufactured by Stryker Bertec Medical Inc 72 0171 R1 1 doc September 2002 F15 43 E A Printed in Canada OPERATIONS MANUAL The GOBED ELECTRIC ACUTE CARE BED Product Number FL17E Product Number for the United States 2500 TM ...

Page 2: ......

Page 3: ...Preventative Maintenance Program 10 1 9 Bed Illustration 11 2 OPERATION GUIDE 12 2 1 Switching On Power 12 2 2 Applying the Brake 12 2 3 Moving the Bed 12 2 4 Positioning Siderails 13 2 5 Head and Foot Boards 13 2 6 Siderail Function Guide 14 2 7 Foot Board Control Panel Guide 15 2 8 Foley Bag Hooks 17 2 9 Foot Prop Rod 17 2 10 Balkan Frame Installation 17 2 11 Patient Restraint Strap Locations 17...

Page 4: ...surface 35 89 cm x 80 203 cm extendable to 82 208 cm and 84 213 cm Minimum Maximum Bed Height 14 to 29 35 5 cm to 73 7 cm Sound Level 58 dBa Fowler Angle 0 to 65 Knee Gatch w o Contour Positioning Knee Gatch w Contour Positioning 0 to 32 0 to 24 Trendelenburg Reverse Trendelenburg 14 to 14 Electrical Requirements 100 V 50 60 Hz 7 5 A 120 V 50 60 Hz 4 8 A 120 V 50 60 Hz 9 8 A w auxiliary outlet 200...

Page 5: ... receptacle is used To help reduce the number and severity of falls by patients always leave the bed in the lowest position when the patient is unattended Leave the siderails fully up and locked when the patient is unattended When raising the siderails be sure you hear the click that signals the up and locked position Pull firmly on the siderail to ensure it is locked into position Always apply th...

Page 6: ...ly dried and has been thoroughly tested for safe operation Do not steam clean hose off or ultrasonically clean the bed Do not immerse any part of the bed The internal electrical parts may be damaged by exposure to water Hand wash regularly all surfaces of the bed with warm water and a mild detergent Wipe cleaned surfaces dry to avoid build up of cleaning substance Inspect the mattress after each u...

Page 7: ...returned items DAMAGED MERCHANDISE Claims for damaged merchandise must be made with the carrier within fifteen 15 days of receipt of merchandise DO NOT ACCEPT DAMAGED SHIPMENTS UNLESS SUCH DAMAGE IS NOTED ON THE DELIVERY RECEIPT AT THE TIME OF RECEIPT Upon prompt notification Stryker Bertec will file a freight claim with the appropriate carrier for damages incurred Claims will be limited in amount...

Page 8: ...when the pedal is toggled to neutral position ____Ensure the siderails raise and lower smoothly and lock in the up position ____Run through each function on the foot board control panel and ensure that each function is working properly ____Ensure all functions are working properly on the siderail control panels inner and outer sides Also check the optional nurse call function ____Raise the bed ful...

Page 9: ...nty Bed Cleaning Hand wash all surfaces of the bed with a soft cloth moistened with a solution of lukewarm water and a mild detergent Wipe the bed clean and dry thoroughly to avoid build up of cleaning solution Mattress Care Inspect the mattress after each use Discontinue use if any cracks or rips are found in the mattress cover which may allow fluid to enter the mattress Failure to properly clean...

Page 10: ...aution following step 11 of the Thigh actuator and the Head actuator replacement procedures found at page 38 and 39 respectively of the GOBED Maintenance manual ____ Optional 120 volt auxiliary outlet working properly ____ Optional photoelectric night light working properly ____ Optional Auto Contour working properly ____ Foot prop rod working properly when Knee Gatch or Auto Contour function is a...

Page 11: ...OKS FOOT END CASING EMERGENCY CRANK OPENINGS FOOT IV POLE HOLDERS SIDE MATTRESS RETAINERS FOOT MATTRESS RETAINERS PATIENT HELPER MOUNTING SOCKETS HEAD BOARD SIDERAIL OUTSIDE CONTROL PANEL PUSH PULL HANDLE FOOT BOARD BRAKE STEER PEDAL FOOT BOARD CONTROL PANEL HEAD SIDERAIL FOOT SIDERAIL SIDERAIL INSIDE CONTROL PANEL ON OFF SWITCH HEAD SECTION CENTER SECTION THIGH SECTION FOOT SECTION SIDERAIL LATCH...

Page 12: ...heel brakes press the red TOTAL BRAKE side of the brake steer pedal fully down on either side of the bed To disengage the wheel brakes toggle the pedal to neutral position 2 3 MOVING THE BED The GOBED is equipped with a 5th wheel steer mechanism see page 11 Bed Illustration activated by a brake steer pedal located at midpoint of the bed on both sides The 5th wheel helps guiding the bed along a str...

Page 13: ...sp the rail pull it towards you and swing it upward towards the head end of the bed until it latches in the up position To engage a foot end siderail the same procedure is required as for the head end siderail however the siderail swings to the foot end of the bed To disengage a siderail lift it up slightly push in the latch lever located under the sleep surface see page 11 Bed Illustration and ho...

Page 14: ...r C Push to raise sleep surface E Push to raise Knee Gatch B Push to lower Fowler D Push to lower sleep surface F Push to lower Kne Gatch INNER CONTROL PANEL Right Siderail Left Siderail A Push to raise Fowler C Push to raise Knee Gatch B Push to lower Fowler D Push to lower Knee Gatch E Push for nurse assistance optional Nurse Call function see section 2 14 page 18 B D F A C E E C A F D B Figure ...

Page 15: ...trol used will light up N NO OT TE E When a lockout switch is used to inhibit a specific function of the siderail control panels the function is inhibited on both sides of the siderail control panel The foot board controls are not affected by the lockout switches Lockout settings are automatically saved in the event of a power failure and restored following resumption of power Fowler Control Switc...

Page 16: ...ss the Trendelenburg switch to deactivate the function green LED will go out and lower or raise the sleep surface to its limit Then position the bed to the desired height Auto Contour optional Pictogram F This figure illustrating the Contour position points to the lockout switch to activate in the foot board control panel to position the bed automatically to the Contour position Contour positionin...

Page 17: ... section lift the prop rod and hold it while raising the Knee Gatch using the control located on the foot board control panel As the Knee Gatch raises the rod will come to pass the catches Release it then and continue to raise the Knee Gatch The foot section will then simply follow the move of the Knee Gatch without being propped 2 10 BALKAN FRAME INSTALLATION A standard Balkan frame can be instal...

Page 18: ...equipped with an optional Nurse Call function allowing the patient to call for nurse assistance by simply pressing the Nurse Call red button The Nurse Call module is integrated to both siderail panel controls next to the control switches see page 14 Included with this option are two Ø1 4 phono jacks located on both sides of the head end case The phono jacks enable the use of a nurse call cord whic...

Page 19: ... aluminium IV pole Two function pendant control with or without hook Product Design Three function pendant control with or without hook Product Design Emergency crank Mattress support extension 10 cushion for the mattress support extension Overhead trapeze Safe working load 150 lb 68 kg Oxygen bottle holder Safe working load 75 lb 34 kg Flip type bed shelf Safe working load 40 lb 18 kg Bed cradle ...

Page 20: ...Two 1 4 flat washers two 1 4 spring washers and two 1 4 20 x 2 1 4 hexagon bolts are needed for the foot board Simply insert the appropriate bolt and the two washer types in the factory installed nut accessible through holes A located on the inner sides of the foot end and the head end casings N NO OT TE E Do not permanently install boards when beds are used in care units where patient may require...