22
MAINTENANCE FUNDAMENTALS - HOT GAS LOOP CONDENSATE UNITS (HV3674RSS.5954, Etc.)
Filter Dryer
Sight Glass
Hot Gas Condensate
Coil and Pan
Receiver
Condenser Coil Fans & Housing
Embraco®
Compressor
Embraco®
Compressor Start
Components
This system also incorporates an overflow
reservoir with heating element to ensure complete
condensate removal.
Indicator Light
Hot gas condensate removal system may also be
equipped with a red indicator light for wicking
material replacement, located in the rear of case.
Wicking Material Replacement
See
TROUBLESHOOTING (TO BE
PERFORMED BY TRAINED SERVICE
PROVIDERS ONLY) - PAGE 1
section in manual.
Hot Gas Loop Condensate Units (Model
HV3674RSS.5954, etc.)
System Operation
Hot gas loop condensate systems utilize a hot
gas serpentine coil that is routed through a
condensate reservoir allowing water to be
heated.
This system may operate in conjunction with a
wicking material that is partially submersed with
warm condenser air passing through it for
evaporation.
Hot Gas Loop Condensing System From
Model HV3674RSS.5954 Shown Above. Your Model May Vary.
Electric Coil Overflow Pan
(And Its Overflow Pan
Electrical Box)
Hot Gas Condensate
Unit Slide-Out
Support Pan