CHAPTER 10: TROUBLE SHOOTING
TROUBLE
CAUSE
SOLUTION
Pump/ Motor does not start
Improper electrical hook up
Blown Fuse
Pump binding or stuck
Motor thermal overload tripped
Thermal overload in starter box
Tripped
Rewire.
Replace Fuse.
Remove (flush) or replace.
Let Cool 30 sec.
Push Button Reset.
Replace Switch.
Call Electrician.
Pump/Motor operates but
has no pressure.
Wrong rotation of motor
Reverse phases.
Pump/Motor operate low
flow and/or low pressure (in
pressure mode)
Clogged inlet strainer due to dirt
Relief Valve (Overflow Valve)
leaking or low pressure adjusted.
Manual Release (Oil Drain) Valve
leaking or loose.
O-ring missing or cut
Clean strainer from dirt.
Adjust Overflow v/v pressure.
Loose outside nut and clockwise
tighten the overflow v/v to close.
Replace O-ring.
Pump/Motor operates but
does not hold system
Fitting loose
Check Valve leakage
Dirt on seal
Release stem out of adjustment
O-ring missing or cut
Tighten or replace fitting.
Flush seal.
Re-adjust stem setting.
Replace O-ring.
Replace Motor.
Summary of Contents for Telford
Page 1: ...Version 1 1 INSTALLATION MANUAL OPERATION INSTRUCTIONS SINGLE POST CAR PARKING LIFT ...
Page 7: ...Version 1 7 WARNING SIGNS ...
Page 8: ...Version 1 8 Fig 2 Fig 3 ...
Page 11: ...Version 1 11 4 4 Lift Dimensions ...
Page 20: ...Version 1 20 Fig 13 Fig 14 Fig15 Fig16 ...
Page 21: ...Version 1 21 Fig 17 Fig 18 Fig 19 ...
Page 24: ...Version 1 24 Fig 24 Fig 25 ...
Page 25: ...Version 1 25 Lock device in the post Fig 26 Fig 27 ...
Page 26: ...Version 1 26 Fig 28 ...
Page 31: ...Version 1 31 Operation box and remote control ...
Page 32: ...Version 1 32 OPERATION STEPS OF OPERATION PANEL CONTROL PANEL ...
Page 38: ...Version 1 38 9 2 HYDRAULIC DIAGRAM ...
Page 44: ...Version 1 44 NOTES ...