Strong Floor-Mate 80E Owner'S Manual Download Page 19

17

9

1

13

5

2

9

18

22

6

14

9

5

12

3

4

7

15

16

11

8

10

ITEM NO.

PART NUMBER

DESCRIPTION

QTY.

1

0202220

Bushing P1-1.125

1

2

0300580

CHAIN #60 RIVETED

40"

3

0301320

CONNECTOR CORD .75M ST 

SHC1038

1

4

0500151

HUB WATERTITE 1"

1

5

1200317

LINK CONNECTING #60 CHAIN

1

6

0700210

GEAR BOX HB682CN210

1

7

1600825

PF Red Bushing 1"x.5"

1

8

1604401

Plug Elec Female

1

9

1921728

SPROCKET H60P21

2

10

2300411

WIRE 12/3 GA SO

45"

11

2300415

WIRE 10/3 GA SO

30"

12

2300417

WIRE 10/4 GA SO

70"

13

88000180

Idler #60 Assy

1

14

0202228

Bushing P1-1.5

1

15

1604388

Plug Elec 240V-30A Female

1

16

1604392

Plug Elec 240V-30A Male

1

17

0301195

CONTROL PANEL FLOORMATE 

80E

1

18

*NON-INV*  26126

1/2-13 x 3" SHSS

1

19

0500149 

HUB WATERTITE .5

3

20

1603296

pf st ell lp .5 - 90deg

3

21

0301350

Connector 1/2 KELSHC1022

3

22

1300225

MOTOR ELEC 7.5HP VEM3710T

1

D

C

B

A

B

C

D

1

2

3

4

5

6

7

8

8

7

6

5

4

3

2

1

E

F

E

F

23701122

SHEET 1 OF 1

POWERTRAIN 

FLOORMATE80 ELECTRIC

DG

D

UNLESS OTHERWISE SPECIFIED:

SCALE: 1:7 WEIGHT: 

REV

DWG.  NO.

C

SIZE

TITLE:

NAME

DATE

COMMENTS:

Q.A.

MFG APPR.

ENG APPR.

CHECKED

DRAWN

FINISH

MATERIAL

INTERPRET GEOMETRIC

TOLERANCING PER:

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL

ANGULAR: MACH      BEND 

TWO PLACE DECIMAL    

THREE PLACE DECIMAL  

A

DO NOT SCALE DRAWING

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

Strong Manufacturing.  ANY 

REPRODUCTION IN PART OR AS A WHOLE

WITHOUT THE WRITTEN PERMISSION OF

Strong Manufacturing IS 

PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

A

12227 ADD: 1/2"-13 X 3" BOLT FOR TENSIONER

DG

2/11/21

BY

DATE

DESCRIPTION

# ECN

REVISIONS

10/1/20

B

12232 DELETE: 0301355, 0301320; ADD: 0500149 (3), 1603296 (3), 0301350 (3)

DG

2/26/21

C

12317 CHANGE 2300417 FROM 56" TO 70"

DF

11/29/21

12/28/21

DG

DELETE: 1300243; ADD: 1300225 & 0700210

12332

D

Summary of Contents for Floor-Mate 80E

Page 1: ...1 Type Floor Mate 80E Model Serial Number...

Page 2: ...2 Floor Mate 80E Owner s Manual Strong Manufacturing Co Inc PO Box 8068 Pine Bluff AR 71611 800 238 5042 870 535 4753 Fax 870 535 4843...

Page 3: ...Table of Contents Preface 4 Important General Safety Information 5 10 A Material Hose 5 6 B Pump 7 C Electronics 7 8 D Guards 8 E Mixer 9 F Eye Protection 9 G Machinery 9 10 H Water 10 Operation 11 1...

Page 4: ...u should remember that the nature of the business that is the mixing and pumping of gypsum or cement and sand aggregates water and admixtures creates the most severe conditions under which machinery c...

Page 5: ...loyer shall minimize the hazard of movement by providing and requiring the use of extension tools E G extended swabs brushes scrapers or other methods or means to protect employees from injury due to...

Page 6: ...600 psi Such hoses can be obtained from Strong Manufacturing Company Do not use other hoses unless specifically advised by the Strong Manufacturing Company Caution ALL HOSES SHOULD BE FITTED WITH FUL...

Page 7: ...p to run dry 3 NEVER RUN THE MATERIALS PUMP DRY because just a few minutes of running dry will ruin the pump stator Always have water or slurry in hopper when running pump C Electronics 1 Read all ins...

Page 8: ...OTECTORS SHOULD BE WORN AT ALL TIMES WHEN OPERATING OR WORKING ON THIS EQUIPMENT D Guards BE SURE ALL MACHINERY GUARDS ARE IN PLACE BEFORE OPERATING THE FLOOR MATE 80E THE GUARDS PROVIDED WITH THIS MA...

Page 9: ...f the mixer inlet grate is removed This switch is crucial to the safe operation of the machine Never under any circumstances remove dismantle or hinder the use of this switch in any way WARNING OPERAT...

Page 10: ...Loose clothing should not be worn by operator or anyone working on or around machine Caution FAILURE TO OBSERVE THE ABOVE WARNINGS CAN RESULT IN SEVERE BODILY INJURY INCLUDING LOSS OF EYES AND POSSIB...

Page 11: ...n first starting start the pump on low and increase speed to desired output speed The following sequence should be adhered to when mixing and pumping the first batch Arrange material in the area where...

Page 12: ...ine is properly primed before a material with heavy aggregate is introduced into the hose the likelihood of a plug at start up is greatly reduced The speed of the material pump should be adjusted to m...

Page 13: ...the maintenance schedule It is essential that greasing be done at the end of the day or job to flush out any cement or gypsum that may have entered the bearings or packing After mixer and pump cleanu...

Page 14: ...SHUTTING IT OUT DO NOT OPERATE THIS EQUIPMENT FROM ANY LOCATION EXCEPT THE OPERATOR S STATION DO NOT REMOVE ANY GUARDS WITHOUT DISENGAGING THE POWER SUPPLY AND LOCKING IT OUT DO NOT STAND OR SIT ON AN...

Page 15: ...ER HIGH VOLTAGE 7967 1 19 0400067 DECAL CAUTION LOCKOUT 1 20 1410135 NUT HEX NYLON INSERT 25 20 4 21 1470131 NP GREASE TWICE DAILY LIL GYP 4 22 1470134 DECAL GREASE NO MORE THAN 150H 4 D C B A B C D 1...

Page 16: ...per Wet Material Elect FM80 1 16 88004020 TROUGH ASSY FLOORMATE80 ELEC 1 D C B A B C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 E F E F 04610402 SHEET 1 OF 1 PUMP 80 FLOORMATE80 ELECT DG A UNLESS OTHERWISE SPE...

Page 17: ...ard Assy 35C D 1 22 88003551 FLOORMATE PADDLE ASSY RL 2 23 88004017 GUARD 2 PIECE CHAIN MIXER 2 516 ASSY 1 24 89008242 Guard Splash Mixer 35CT 35DT 2 25 89011404 KEYSTOCK 1 4 X 2 2 D C B A B C D 1 2 3...

Page 18: ...AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF Strong Manufacturing Inc IS PROHIBITED PROPRIETARY AND CONFIDENTIAL NEXT ASSY USED ON APPLICATION DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL ANGULAR MA...

Page 19: ...KELSHC1022 3 22 1300225 MOTOR ELEC 7 5HP VEM3710T 1 D C B A B C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 E F E F 23701122 SHEET 1 OF 1 POWERTRAIN FLOORMATE80 ELECTRIC DG D UNLESS OTHERWISE SPECIFIED SCALE 1...

Reviews: