Technical data:
STROCO Fuel-burning
heater type 15.00 M:
Fuel-burning heater unit with integrated automatic controls and alarm
functions.
Dimensions L x W x H:
409 x 178 x 307 mm
Weight:
17.5 kg
Connections:
The fuel-burning heater is connected to the electrical installation, fuel
tank and water/heating system of the vehicle.
Supply voltage:
24 or 12V DC
Fuel:
Diesel EN 590
Fuel consumption:
approx. 1.25 kg/h
Fuel filter:
Filter area: 1937 cm
2
Filter degree: 0.02 mm
Connection: 1/4”RG
Heating effect:
Output approx. 13 kW
Power consumption:
approx. 5A at 24V DC (incl. circulation pump)
9A at 12V DC (incl. circulation pump)
Combustion data:
CO
2
: approx. 10%, Soot figure: 0-1 Bacharach
Circulation pump:
approx. 22.5 l/min.
Fuel pump:
Operating pressure: 8 bar (kg/cm
2
)
Nozzle:
1.46 kg/h (0.40 Usgal/h 80°S)
Photo unit:
Type LDR
Over boiling protection:
Type Therm-o-disce
Breaking temperature 110°C
Control thermostat:
NTC 10 K sensor. Boiler temperature:
High: making/breaking approx. 73/80°C
Low: making/breaking approx. 55/60°C
Cab ventilation: Start approx. 50°C/Stop approx. 45°C.
MAX. AMBIENT
TEMPERATURE:
80°C
IMPORTANT! THE HEATER SYSTEM MUST BE FILLED WITH AN ANTI-CORROSIVE
ADDITIVE (E.G. 40-60% ANTI-FREEZE) (SEE ENGINE SPECIFICATIONS).