33
MA_VEB100-1-2-2W-4-5_A3-1_190627_en.doc
3.5
Feed dogs
The machine is equipped ex works with the pyramid-toothed feed dog. After loosening
the two screws, its motion towards the stitch plate can be adjusted.
3.5.1
Adjusting the feed dog (Fig. 11)
A T T E N T I O N !
Switch off the machine electrically!
-
Set the stitch length to 8 mm (for Cl. VEB100-4 to 5 mm).
-
Clamp down the feed dog so that it lies parallel to the stitch plate and
the lower part of the tooth protrudes beneath the bottom of the stitch plate. It
must not collide with the sides of the stitch plate opening amd should be set
forwards as far as possible towards the needle.
Clamp a piece of paper with 0.2 mm to the tip of the needle 2 mm in front of the
centre of the presser.
Fig. 11