21
MA_VEB200-1-2_A2_181015_en
3.6
3.6.1
Feed plates
Setting the feed plates
A T T E N T I O N !
Switch off machine electrically!
The feed plates should tilt easily and should sit close to the needle plate. To
guarantee a material feed free of twist, the pressure should be set to 12N on
the left and to 6N on the right side, measured at the pivot of the feed plates.
Tense the tension springs correspondingly (Setting screws on the left back side
and on the right on the top side of the material support arm).
3.6.2
When lifting the cloth support arm the feed plates are pressed downwards.
Adjustable eccentric bolt (1) in cloth support arm extension and threaded pin (2)
in lever (3) serve as limit stop. With the cloth support arm being in its utmost
upper position there should be a play of approx. 1 to 2 mm between lever and
bolt to guarantee a secure pressing of the feed plates to the needle plate at any
stitch depth regulation.
Setting the feed plate lifting (Fig. 10)
Fig. 10