20
MA_218D-TP-R_A4_181015_en
3.7
The plunger forces the sewn material from underneath into the needle plate
opening, so that the needle can penetrate the sewing material.
Plunger
3.7.1
Removing the plunger (Fig. 10)
A t t e n t i o n !
Switch off machine electrically!
1.
Unscrew threaded screw (2) with plunger check screw (3), until it is
flushed with the plunger sleeve. This will cause the plunger spring to relax.
2.
Force plunger down using a screwdriver or similar, until the surface of the
plunger setscrew (3) protrudes beyond the screw used for plunger
adjustment (2).
3.
Unscrew plunger check screw (3)
4.
Remove needle plate, see “3.1.1 Removing the needle plate (Fig. 1)”.
5.
Pull plunger out from the top.
Fig. 10