![Stringway MS140L Instruction Manual Download Page 2](http://html1.mh-extra.com/html/stringway/ms140l/ms140l_instruction-manual_1384737002.webp)
The machine can only be used when it is clamped to the table. Slide the table clamp through the frame
and position the machine so far from the edge of the table that the clamping screw is under the centre of
the frame. Tighten the clamping screw firmly.
A3 Fastening the lever of the drop weight system.
Loosen the clamping screw a little and slide the lever into the tension head with the screw in the slot.
Tighten the clamping screw.
A4. Mounting the turntable over the shaft.
Slide the turntable over the shaft. Check if there is grease inside the delrin bush, if not add a thin layer
of grease into the bearing.