Remedying Faults in PP 1207– Klöckner Möller
Remedying faults PP 1207
page 24 – April 2005
C. If magnetic switch is properly adjusted and still
does not work, it must be tested as follows.
Remove connection
cable from the terminals
with a screwdriver.
Ensure that the sensor is
correctly adjusted
If a connection has no
function, sensor is faulty
and must be replaced
Apply continuity tester as follows
Brown: input side
Blue: output 1, Black: output 2; both
normally open, and closed when switch is
engaged (see mimic diagram on the switch)
2.3 Machine does not start
C. Magnetic switch misaligned or faulty