Replacing a U779V Fabric Switch
Removing and Replacing a U779V Fabric Switch
A-21
N O T E
You must be logged in as
SysAdmin
in order to issue the
board_admin
command.
c. Confirm that the U596V PCI adapter has been added by issuing the
list_boards -long
request of the
analyze_system
subsystem. The
value listed in the
State
row should be
STATE_DUPLEX
.
Final Steps
After you replace the fabric switch, you may need to perform the following procedures:
If you need to log in to the fabric switch (for example, to check and set up a
customer’s IP address), use one of the methods described in
If you change the fabric switch’s IP addresses, you
must
stop and restart the
storage_monitor
daemon with the
start_monitor
command macro. See
Logging In to the Fabric Switch
Log in to the fabric switch using one of the following methods.
To log in to the fabric switch from a PC
1. From a PC, open a Web browser. In the browser’s Address field, enter the default
IP address of the fabric switch:
Controller A:
http://10.10.1.18
Controller B:
http://10.10.1.19
2. Log in to the fabric switch using default values:
Default login name:
admin
Default password:
password