Replacing a U779V Fabric Switch
A-20
Stratus ftServer V 6624 Hardware Installation Guide
(R005S)
12. Replace the bezel (
a. Grasp the bezel on its right and left sides.
b. Push the bezel on the front of the fabric switch until it snaps on to the ball studs.
Figure A-18. Replacing Bezel
13. If you removed the 1U bezels above and/or below the fabric switches, reattach
them using the method described in step
14. Issue the OpenVOS commands to bring up the HBA that connects to the
U779V fabric switch. The HBA (that is, the PCI adapter) that supports the fabric
switch is typically the U596V Dual-Port 16-Gb Fibre Channel PCI Adapter.
a. Determine the correct device ID of the U596V PCI adapter by issuing the
list_boards -long
request of the
analyze_system
subsystem.
b. Issue the
board_admin
command, specifying the correct device id for the
device_id
argument and
add
for the
action
argument, as follows:
board_admin
device_id
add
bezel