4-84
Umbilical Hose
Required Tools
•
5
⁄
16
” nut driver or standard screwdriver
•
1
⁄
4
” nut driver
•
5
⁄
32
” allen wrench
• Cutters
Hardware
• Wire
tie
• 10-32
x
3
⁄
8
” slotted screws (x7)
•
1
⁄
4
- 20 x
1
⁄
2
” button head cap screws (x2)
Removing the umbilical hose
1.
Remove the top panel. See
Removing the top panel on page
2.
3.
Remove the upper electronics bay cover. See
Removing the upper electronics bay cover
4.
Using a
5
⁄
16
” nut driver or standard screwdriver, remove the right side access panel
mounting screws and remove the panel. See
Figure 4-143: Right side access cover mounting screw locations
Remove the 7
mounting screws.