uPrint/uPrint SE Service Manual
4-83
Figure 4-140: Disconnecting the umbilical cable
5.
Disconnect the model and support thermocouple wires by pulling outward. See
Figure 4-141: Thermocouple wire locations
6.
Using a
1
⁄
4
” nut driver or standard screwdriver, remove the 3 mounting screws and
remove the TC Amp board. See
Figure 4-142: TC Amp board mounting screw locations
Installing the TC Amp board
1.
Align the TC Amp board with the mounting holes.
2.
Using a
1
⁄
4
” nut driver or standard screwdriver, reinstall the 3 mounting screws.
3.
Reconnect the model and support thermocouple wires.
4.
Reconnect the umbilical cable.
5.
Reinstall the right side access panel.
6.
Reinstall the side panels. See
Installing the side panels on page
7.
Reinstall the top panel. See
Installing the top panel on page
Disconnect the
umbilical cable
Disconnect the support
thermocouple
Disconnect the model
thermocouple
Remove the 3
mounting screws
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...