2. Verify that the filter is positioned correctly before replacing the cover and securing the clips.

Figure 4: Securing the cover

Caution:

Do not cover the exhaust outlets, as this restricts the airflow and causes overheating.

Cover

Pre-filter

pad

Combined

filter

Summary of Contents for ProAero

Page 1: ...DOC 01003 Rev D ProAero Air Extraction System Installation and User Manual...

Page 2: ...or consequential damages in connection with the furnishing performance or use of this material Stratasys makes no warranty of any kind with regard to this material including but not limited to the imp...

Page 3: ...ion and Skin 4 Filter Selection 4 Warning and Information Labels 5 Preparation 5 Installation 7 Connecting to the Power Supply 7 Connecting to the 3D Printer 7 Operation 8 Setting the Desired Airflow...

Page 4: ...1 Copyright 2020 Stratasys All rights reserved Overview Figure 1 Air extraction system front Figure 2 Control panel Cover Indicators and controls Cover clip Air inlet Filter change indicator Motor spe...

Page 5: ...ser s needs The rear outlet can be covered using the plate screwed to the underside of the extraction system The air then exits through the opening under the system When the rear outlet is in use cove...

Page 6: ...electric shock or injury 1 Always disconnect the system from the mainpower supply before servicing 2 Use this system only as described in this manual 3 Connect the system to a properly grounded outle...

Page 7: ...agitates and releases some of these particulates to the surroundings enabling them to enter the respiratory system and eyes of the operator Additionally depending on the materials used the particulat...

Page 8: ...nt to the label Bottom panel Electrical hazard Removal of panels with this label exposes electrical components Bottom panel Warning Turn the power to the system off before opening the panel with this...

Page 9: ...ll rights reserved 2 Verify that the filter is positioned correctly before replacing the cover and securing the clips Figure 4 Securing the cover Caution Do not cover the exhaust outlets as this restr...

Page 10: ...azard Connecting to the 3D Printer 1 Connect the control cable from the extraction system shown in Figure 3 page 2 to the AUX 24V connector in the connection panel on the back of the J55 Figure 5 J55...

Page 11: ...the motor speed to maintain the correct flow rate and compensate for any loss in performance To adjust the airflow Press to increase airflow and press to decrease airflow The level of airflow is indi...

Page 12: ...ion system contains a pre filter pad and a combined filter Replace the filters regularly To maintain performance it is important that the filters are replaced with identical replacement filters To re...

Page 13: ...ever comes first Combined filter every 350 printing hours or 6 months or sooner if the filter replacement indicator turns red and flashes Figure 7 Filter replacement indicator on control panel To repl...

Page 14: ...8 Filter elements To replace the combined filter 1 Turn off the system power switch 2 Open the clips on the sides of the system andremove the cover 3 Lift the filter out of the system Do not activate...

Page 15: ...he customer s responsibility to verify that the disposal of filters complies with all local and or industrial regulations System Specifications Capacity 75 m h 44CFM Weight 10 5 kg 23 1 lbs Fan type C...

Page 16: ...3 Copyright 2020 Stratasys All rights reserved Filter Information Filter Type Construction Efficiency Pre Filter Pad Glass Fiber F7 96 2 microns Combined Filter HEPA Maxipleat Construction with Webbin...

Page 17: ...THE 3D PRINTING SOLUTIONS COMPANY www stratasys com _____ c support stratasys com Copyright 2020 Stratasys Ltd All rights reserved DOC 01003 Rev D...