If the UV level measured is not acceptable, the wizard calibrates the UV lamp by
adjusting the current supplied to it, and then tests it again.
When all UV tests have finished, the results are displayed, showing the condition
of the lamps after calibration (see Figure 4-116 below).
Figure 4-116 Results and condition of UV lamps after calibration
After examining the UV calibration results:
1. Click
Next
.
2. Remove the UV sensor and close the printer cover. After confirming the items
listed in the wizard screen, click
Next
.
Figure 4-117 UV sensor removal
If the results are not acceptable for quality printing, this is indicated in the final
wizard screen.