Operating & Maintaining the Eden350V 3D Printer
6–54
DOC-03050 Rev. A
UV measurement
The
UV
lamps
power
up
and
stabilize.
(This
takes
several
minutes.)
Then,
the
block
passes
over
the
sensor
and
the
wizard
compares
the
measured
radiation
to
the
recommended
level
for
each
UV
lamp
and
printing
mode.
During
this
process,
which
takes
20–40
minutes,
you
need
to
monitor
the
progress
as
displayed
in
the
wizard
screen.
Figure 6-85: UV measurement progress
¾
When
using
a
stand
‐
alone
radiation
meter,
reset
the
meter
and
enter
the
reading
(measurement)
when
you
are
prompted
to
do
so.
Figure 6-86: UV measurement dialog box
If
the
UV
level
measured
is
not
acceptable,
the
wizard
calibrates
the
UV
lamp
by
adjusting
the
current
supplied
to
it,
and
then
tests
it
again.
When
all
UV
tests
have
finished,
the
results
are
displayed,
showing
the
condition
of
the
lamps
after
calibration
(see
Figure 6-87: Results and condition of UV lamps after calibration