Quick Start Guide

ViSion.net 8-Port
diGital inPut Module

 443581626883

WARNINGS AND NOTICES

When using electrical equipment, basic safety precautions should always be followed including the following:

•  For indoor, dry locations use only. Do not use outdoors.
•  Do not mount near gas or electric heaters.
•  Equipment should be mounted in locations and at heights where it will not readily be subjected to 

tampering by unauthorized personnel.

•  The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition 

and void warranty.

•  Not for residential use. Do not use this equipment for other than intended use.

©2021 Signify Holding. All rights reserved.

All trademarks are owned by Signify Holding or their respective owners. The 
information provided herein is subject to change, without notice. Signify does 
not give any representation or warranty as to the accuracy or completeness of 
the  information included herein and shall not be liable for any action in reliance 
thereon. The information presented in this  document is not intended as any 
commercial offer and does not form part of any quotation or contract, unless 
otherwise agreed by Signify. Data subject to change.

CUSTOMER SERVICE

If you have any questions regarding this product, 
please contact Customer Service by phone at 
+1 214-647-7880 or by email at 

entertainment.

[email protected]

.

2

reQuireMentS

•  The Vision.Net 8-Port Digital Input Module is pr24 V DC 

over the Vision.Net interface. Do not attempt to power the module 

from a separate power supply. 

•  The recommended wire for interfacing Vision.Net is Belden 1583a 

(Cat5e, 24 AWG, Solid).

•  The recommended wire size for connecting sources is 16-28 AWG.

To connect Vision.Net 8-Port Digital Input Module to Digital Input 

Sources:

Step 1. 

Remove applicable screw-down connector from module. 

Step 2. 

Prepare wire and insert into connector observing polarity of 

the source, if required. Use a slotted screwdriver to tighten 

the screw down terminals.

Step 3. 

Align and evenly re-insert the connector back into the 

module.

SURFACE MOUNT BRACKET CAN

BE MOUNTED HORZONTALLY

OR VERTICALLY AS SHOWN

LED INDICATORS

PWR: Solid green when module is powered
TX: Flashes green when signal transmitted
RX: Flashes red when signal received

VN: Flashes red to indicate the binary Vision.Net ID
IN: Flashes red to indicate which inputs are active
OUT: Flashes red to indicate which outputs are active

LSB - Least Significant Bit
MSB - Most Significant Bit 

1-8: Flashes green status of inputs. Display using MODE button.

CONFIGURATION BUTTONS

MODE: toggles LED display between VN, IN, and OUT 
PRM: advanced programming for Certified Technicians
INC: advanced programming for Certified Technicians
DEC: advanced programming for Certified Technicians