Strand Lighting 63035 Installation & Operation Manual Download Page 3

Vision.net RS232 Interface Port

Installation & Operation Guide

1

Important Safeguards

TABLE OF CONTENTS

Overview ................................................................................................................................... 2

Vision.net System Overview.............................................................................................  2

Vision.net RS232 Serial Interface Port Overview ............................................................  2

Installation ................................................................................................................................. 3

Installation Steps ...............................................................................................................  3

Operation ................................................................................................................................... 4

Communication Modes .....................................................................................................  4

ASCII Codes For Vision.net Show Control Protocol .......................................................  4

Specifications ............................................................................................................................ 5

When using electrical equipment, basic safety precautions should always be followed 
including the following:

a.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

.

b. Do not use outdoors.

c. Do not mount near gas or electric heaters.

d. Equipment should be mounted in locations and at heights where it will not

readily be subjected to tampering by unauthorized personnel.

e. The use of accessory equipment not recommended by the manufacturer

may cause an unsafe condition.

f. Do not use this equipment for other than intended use.

g. Refer service to qualified personnel.

SAVE THESE INSTRUCTIONS

.

WARNING:  

You must have access to a main circuit breaker or other power 

disconnect device before installing any wiring.  Be sure that power is disconnected 
by removing fuses or turning the main circuit breaker off before installation. 
Installing the device with power on may expose you to dangerous voltage and 
damage the device. A qualified electrician must perform this installation.

WARNING:  

Refer to National Electrical Code® and local codes for cable 

specifications. Failure to use proper cable can result in damage to equipment or 
danger to persons.

CAUTION:   

Wire openings MUST have fittings or lining to protect wires/cables 

from damage.  Use 90° C copper wire only!

Summary of Contents for 63035

Page 1: ...UJ 0 J z 0 a UJ 0 0 z 0 I I C z Strand Lighing RS232 Serial Interface Port Model 63035 ...

Page 2: ... seulement et est sujet à changements sans préavis La compagnie Philips Strand Lighting n assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises à jour de ce manuel veuillez s ll vous plait contacter le bureau de Philips Strand Lighting le plus proche Information contained in this document ...

Page 3: ...nel e The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition f Do not use this equipment for other than intended use g Refer service to qualified personnel SAVE THESE INSTRUCTIONS WARNING You must have access to a main circuit breaker or other power disconnect device before installing any wiring Be sure that power is disconnected by removing fuses or turni...

Page 4: ...iven a unique ID or address in order to interact properly The ID identifies the device on the network and allows the device to avoid network collisions when transmitting data Vision net RS232 Serial Interface Port Overview The Vision net RS232 Serial Interface Port Strand Part No 63035 allows integration with the Vision net Network using standard RS232 communication The RS232 Interface has the abi...

Page 5: ...dard deep rough in box not included Secure with two supplied mounting screws Step 4 Snap faceplate into place A standard Windows compatible computer can be connected to the Vision net Network using the RS232 Interface Port The port accepts a standard one to one 9 pin serial cable up to 25 feet in length RS232 Interface Port PC Computer Pin 1 NU Pin 1 NU Pin 2 TX Pin 2 RD Pin 3 RX Pin 3 TD Pin 4 NU...

Page 6: ...it 1 Stop Bit 19200 Baud 9600 Baud Protocol Binary Protocol ASCII Vision net Command RS232 Protocol Vision net Command RS232 Protocol Start Preset Toggle Down Toggle Up Learn Preset Slider Level Learn Submaster Manual Expander Group Start Raise Start Lower Stop Raise Lower SP rrr pp tt cr TD rrr ccc cr TU rrr ccc cr LP rrr pp cr SL rrr ccc lll cr LS rrr ss cr MN rrr ggg lll lll cr EG rrr ee cr EG ...

Page 7: ...ear All Links 1 Do not clear ee Expander Group 0 15 mm Mode 0 All modes ff Index of First Channel 1 127 fff First Room 1 255 n Button LED 1 255 a Action 0 1 Off On or Button Up Down for Send Mimic Command 0 1 Button Down Up for Console Button Command 0 1 LED Off On for Console Button Command SPECIFICATIONS Electrical Input Power 18 26 VDC powered from Vision net network Current 20mA Temperature St...

Page 8: ...Part No 2 450200 020 ...