Multisport
Eco Range
ZI de Bel Air 44850 LE CELLIER FRANCE [email protected] Tél. +33 (0)2 40 25 46 90
IA452XME3000_D - Installation 452XME3000.docx
Page 5
YBJ30
2
4
1
3
P
100-240V
50/60Hz
Q
1
2
3
4
YBJ30
T
R
B
K
T
J
B
Cable transmission model - Electrical installation
Caution: the scoreboard must not be connected to mains before installation has been fully completed.
Control cable and wall junction box
The transmission cable supplied is a telephone cable: type 2 pairs 6/10
ths
.
Mount the wall junction box YBJ30 onto the wall close to the scoring table.
Connect the control cable (Q) on the connector (T) of the scoreboard making sure that the colour code is followed (Please note –
RS485: Rx+ and Rx- must be connected on a twisted pair).
Extract the electronic rack (R) from the scoreboard: unscrew the two nuts (B) with a 7 mm pipe spanner, then let the rack (R) slide
downwards.
Put the connector (T) inside the scoreboard through the grommet (K).
Plug the connector (T) on the electronic circuit board and fix the cable on the rack with a plastic collar (J).
Put the rack (R) back inside the scoreboard and screw the two nuts (B).
Fix the control cable into place making sure that it does not run alongside the 100-240V mains cables.
Connect the end wires into the junction box YBJ30, making sure that the colour code is followed. If several units are connected
together, their cables must be wired in parallel in the wall junction box.
Mains cable (P)
Connect the cable (P) to 100-240V electrical power supply. The electrical power supply should be protected via a bipolar 4A circuit
breaker (not supplied). Bipolar circuit breaker must be easy to reach.
Control cable (Q): (1) = GND = blue wire / (2) = Rx+ = white wire / (3) = Rx- = grey wire / (4) = +24V = transparent wire
End of the installation
Turn on the power.
Try out the scoreboard operating functions (see operating functions).