14
STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de
08.2018
I
Operating instructions -- PowerMax
cam unit PMU
Power
Max
PowerMax cam unit SN5650-PMU-0330
—
SN5650-PMU-1200
1
2
1
2
2
1
Step 2
To loose the locking, push at first the clamp,
respectively the clamps, in direction OPEN
1
.
Then the clamps can be removed
2
(picture 4).
Step 3
Screw the safety ring bolts (SN1594) in the
plate to be able to lift it with a crane. First lift
the mounting plate out of the centering nut
(picture 2). The fit was produced with high
precision and a close tolerance. If necessary hit
with a plastic hammer in front of the plate and
avoid a canting of the mounting plate. As soon
as the mounting plate is lifted from the nut,
pull the plate ahead (picture 5).
picture 4
1
2
1
2
picture 5