![Strack PowerMax SN5650-PMO-0330 Operating Instructions Manual Download Page 10](http://html1.mh-extra.com/html/strack/powermax-sn5650-pmo-0330/powermax-sn5650-pmo-0330_operating-instructions-manual_1383295010.webp)
10
STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de
I
Operating instructions -- PowerMax
cam unit PMO
Power
Max
PowerMax cam unit SN5650-PMO-0330
—
SN5650-PMO-1200
11.2020
8. Production
During the production no particular precautionary measures have to be taken, which exceed the valid
operating safety regulations paragraph 3.
Attention:
If attachments are removed during the assembly process, they must be secured again with
Loctite 242.
Notes on tightening torques:
Advice:
Please secure that the
STRACK
cams especially the gas springs are not dipped in fluid.
If you are using for example aggressive drawing oils during the production, make a controlled
drain for them (drainage borings, cutouts and so on), so that the fluids are directed away from
the gas springs.
Thereby seal damages are avoided.
Tip:
Control the nitrogen pressure of the gas springs in regular intervals, to detect changes in the
pressure level in time. During maintenance works you have to consider a correct return of the
cam slide.
Advice:
The cam units are equipped with low-maintenance slide elements out of bronze with solid
lubricant. In normal case lubrication is not necessary.
A lubrication may only be effected in case of need with the following lubricants:
Company
Oils
Greases
AGIP
Potra ATF
Agip GR MU 2
BP
Autran DX II
Energrease
ESSO
ATF Suffix A
Nebula EP 2
ESSO
ATF - D
Beacon EP 2
OMV
ATF Serie
OMV signum CX 2
SHELL
Donax TM
Retinax LX
SHELL
Donax TF
Screws
DIN EN ISO 4762-10.9
M6
M8
M10
M12
M16
M20
Tightening torque [Nm]
14
33
65
121
302
590
All data
without guarantee.