4.1.1  Operating Mode (Do not change) 

 
The operating mode switches (S1

S2

S3

S4 & S8) are set to normal mode (mirror mode). Do not 

change this setting. 

 

Important 

Changing the operation mode switches will result in loss of data. 

 

 
 
 

4.1.2  Write Cache Mode 

 
This bit sets the write cache mode. If set to "OFF" (Default Setting meaning Write Cache Enabled), the 

SATA Mirror Drive

 will signal completion of command processing to the host computer when the data 

has been written to cache memory. If set to “ON”, the 

SATA Mirror Drive

 will signal completion of 

command processing to the host computer when data is actually written to the drive unit. 

 

Always observe the shutdown procedure specified for the host 
computer’s operating system. In delicate situations, try to wait at 
least 10 seconds to be sure that both the access indicator and the 
drive status indicator have stopped flashing before shutting off the 
power. Turning off the power while the access indicator or the drive 
status indicator remains lit may result in loss of data currently located 
in cache memory. 

Important

 

 

 
 
 

4.1.3 Revival Reconstruction 

 
If the bit is set to "OFF" (Default Setting meaning Revival Reconstruction Enabled), the 

SATA Mirror 

Drive

 will attempt to do data reconstruction after Error Recovery Procedure fails while in Retry Mode. 

The 

SATA Mirror Drive

 will not remain in Degraded Mode but instead, will automatically do data 

reconstruction to trying to revive the drive up to two times. 
 
 
 

4.1.4 Buzzer 

 
If the bit is set to "OFF" (Default Setting meaning Buzzer Enabled), the buzzer will sound when any error 
is detected. In the event of a drive unit failure, the buzzer will continue to sound until the failed drive unit 
is replaced. The buzzer can be stopped if the switch position is changed to “ON”. 
Set back the buzzer to "OFF" after the failed drive unit has been replaced. 
When an external bracket is used for the 5" Drive Bay installation, please make sure that Bit 7 setting of 
the Dip Switch is set to Enable. The buzzer sound can be turned ON and OFF through the Buzzer switch 
in the external bracket. If the buzzer is turned OFF prior to drive replacement, slide it back to ON after 
the new drive unit has been inserted. 
 

 

9

Summary of Contents for AXRE-U080SA

Page 1: ...3 5 Form Factor Mirror Drive Serial ATA MODEL AXRE U Series User s Manual P N A203649 Revision 1 4e...

Page 2: ...3 5 Form Factor Mirror Drive SATA Model User s Manual This page is intentionally left blank...

Page 3: ...packaging materials in case you need to ship the SATA Mirror Drive in the future This product is sealed in an antistatic and moisture proof bag before shipping Open the bag only when you are about to...

Page 4: ...or serious injury to the user or severe damage to the product Caution Indicates a potentially hazardous situation that may result in serious injury to the user or damage to the product Important Indi...

Page 5: ...fy this product STR V cannot guarantee the performance or safety of any product that has been repaired by the customer or by an unauthorized third party Repairing by your self may result in fire elect...

Page 6: ...ternal components of the SATA Mirror Drive y Do not turn on the power immediately after turning it off or turn off the power immediately after turning it on Leave at least 20 seconds in between succes...

Page 7: ...ng the shutdown procedure for your host computer The SATA Mirror Drive uses cache memory to store the data frequently accessed from the HDD Except in emergencies you must follow the operating system s...

Page 8: ...other static sensitive devices touch a metal object such as the metal enclosure of the host computer to discharge any static electricity from your body y Always handle components carefully Never touch...

Page 9: ...puter ensure that the drive unit is installed horizontally as in A below Do not install the unit vertically i e with the connector facing either up or down as in B Furthermore when installing the unit...

Page 10: ...ttings 6 3 2 Mounting in the Host Computer 6 3 3 Cable Connection 7 3 4 Turning on The Main Power 7 4 Settings 8 4 1 DIP Switch 8 4 1 1 Operating Mode Do not change 9 4 1 2 Write Cache Mode 9 4 1 3 Re...

Page 11: ...3 5 Form Factor Mirror Drive SATA Model User s Manual Appendix A Specifications 22 Appendix B Accessories 23 Appendix C Factory Default Setting 24 Appendix D Replacement Parts 25 Information 26 ix...

Page 12: ...standard Serial AT HDD No special device drivers needed Compatible with most operating systems z Compact size 3 5 HDD Form Factor Full Compliant 101 6 mm x 147 mm x 25 4 mm W x L x H z Serial ATA Inte...

Page 13: ...Do not turn off the host computer while the SATA Mirror Drive is still rebuilding the data to prevent loss of data or failure When a sector of the fully functional drive unit can not be read during d...

Page 14: ...Names Power Connector SATA Connector Controller Unit Dip Switch Status Signal Voltage Selection Switch Access LED MODEL AXRE U SA Model Name EC YB Verion S N Serial Number Drive 1 LED Drive 2 LED Exte...

Page 15: ...irror Drive SATA Model User s Manual 2 2 Dimensions 101 6 3 144 5 41 6 60 16 9 25 4 6 4 3 2 95 2 61 44 5 3 2 3 6 32UNC 4 4 6 32UNC 2 2 1 SATA Mirror Drive Unit mm 61 0 Mounting Screw Holes 60 0 Mounti...

Page 16: ...3 5 Form Factor Mirror Drive SATA Model User s Manual 2 2 2 5 inch Bay Mirror Drive Installation Attachment 4 4 6 32UNC Mounting Screw Holes Unit mm 146 0 43 0 5...

Page 17: ...supply of the host computer is turned off 3 2 Mounting in the Host Computer When mounting in the host computer use the attached mounting screws and the specified mounting holes The mounting screw hol...

Page 18: ...Before turning on the host computer gently press the front face of each drive unit to confirm that these are firmly inserted and verify if the lever lock is firmly fixed Next turn on the host compute...

Page 19: ...s default DIP Switch settings are set to maximize its performance 1 2 3 4 5 6 7 8 ON DIP Switch Functions Default Switch position S1 S2 S3 Mode Bit 1 2 3 Normal Mode OFF Normal S4 Reserved OFF S5 Writ...

Page 20: ...tus indicator remains lit may result in loss of data currently located in cache memory Important 4 1 3 Revival Reconstruction If the bit is set to OFF Default Setting meaning Revival Reconstruction En...

Page 21: ...en simultaneously Any of the above 5 1 2 Drive Status Indicator 1 When the power is turned on 1 2 Processing a command from the host computer Green 3 Processing an internal command Either of the above...

Page 22: ...the event of a failure the buzzer will beep at the interval specified below Drive unit 1 failed Beep Beep Buzzer 0 3s 3 2s Drive unit 2 failed Beep Beep Buzzer 0 3s 3 1s 0 3s 0 3s Beep Beep System st...

Page 23: ...l Connector Pin Assignment 1 GND 2 3 3VDC Default 5VDC Option 3 Status Bit 2 4 Status Bit 1 5 Status Bit 0 6 GND Status output is transmitted in 3 bit signals as follows Bit 2 Bit 1 Bit 0 Status 0 L L...

Page 24: ...ecification 3 3V Default max Output High Voltage VDC 5 0V Option Voltage Selectable Through S3 Output Low Voltage V max 0 4V DC Output Sink Low Current max 20mA Current Output Source High Current max...

Page 25: ...ve External LEDs can be connected as shown below The brightness can be adjusted by any resister from 0 ohm to 150 ohm CN14 Connector Part Name Maker Mirror Drive Header DF3Z 9P 2H 50 HIROSE Electric C...

Page 26: ...ition 1 Reserved 2 Reserved 3 5V 1 CN6 5 4 GND 5 Buzzer Stop The Pins reserved must be open Recomended circuits to stop buzzer Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Short Buzzer Stop Open Buzzer On CN6 Connec...

Page 27: ...een Normal operation Orange Drive unit 1 failure Replace the drive unit 1 with a new drive unit Orange Drive unit 2 failure Replace the drive unit 2 with a new drive unit Orange Controller unit failur...

Page 28: ...replace the specified drive unit with a new drive unit Leaving the SATA Mirror Drive with a single operational drive unit for an extended period will result in data loss if the other drive unit fails...

Page 29: ...When both drive units seem to have failed replace the units according to the following procedure This is an emergency recovery procedure data corruption may or may have already occurred Important To a...

Page 30: ...ator of the replacement drive unit will flash orange 1 second interval Important Do not remove the drive unit while data rebuilding is underway 16 During data rebuilding the drive status indicator of...

Page 31: ...r the other and then pull it out 6 Insert the drive units into the new controller unit Make sure drive unit numbers 1 and 2 are kept as they were before replacement One after the other push firmly the...

Page 32: ...th the use of the grooved marking carefully slide the lever to the right 13 Confirm that the front levers are fixed 14 Several seconds after replacing the drive unit data rebuilding will start The dri...

Page 33: ...5 mm x 43 0 mm SATA Mirror Drive 600 g Weight 5 inch Bay SATA Drive Installation Attachment 900 g Voltage VCC 4 85 V 5 25V DC DC Power supply ripple max 1 100mV p p 0 20MHz Power startup time 2 5 100...

Page 34: ...3 5 Form Factor Mirror Drive SATA Model User s Manual Appendix B Accessories The SATA Mirror Drive AXRE U Series is shipped with following accessories y Mounting screws 4pcs 23...

Page 35: ...ows DIP Switch Settings Default Setting Function Mode SW No DIP SW SETTING S1 OFF S2 OFF Normal Mode Mirror Mode S3 OFF Reserved S4 OFF Write Cache Write Back Enabled S5 OFF Revival Reconstruction Ena...

Page 36: ...Replacement Parts The following are supplied as user replaceable parts Part name Part number A203791 A203945 80 GB drive unit Replacement drive unit for AXRE U080SA SA1 SA2 A204059 Replacement control...

Page 37: ...For more information about this product please contact your distributor Distributor s information Product Records Model Name AXRE U YB Revision Serial Number Manufacturer This product is manufactured...

Reviews: