Installation Instructions
Step 2: Connect to the electricity
supply
Warning:
This appliance must be
earthed.
1. The appliance must be installed
by a competent electrician using a
double pole control unit of
30 ampere
minimum capacity,
with 3mm minimum contact
separation at all poles.
2. Access to the mains terminal is
gained by opening the terminal
block cover at the rear of the
appliance (use a small flat-bladed
screwdriver).
3. Connection should be made with
suitable twin and earth heat
resistant flexible cable, minimum
4mm
2
, which is suitable for use up
to 25 amps.
4. First strip the wires, then push the
cable through the cable clamp in
the terminal block cover.
5. Connect the cable to the terminal
block and tighten the cable clamp
screw.
6. Close the terminal box, ensuring
that the cover is engaged on the
locking tabs.
Step 3: Check edging strip
The edging strip is factory fitted to
the front side edges of the appliance
front frame. This strip provides the
c a b i n e t r y with extra protection from
any escape of heat.
When installing the product, ensure
that the edging strip is correctly located
on the outer edges of the front frame,
before positioning and securing the
appliance to the cabinet.
When securing the appliance, the
fixing screws provided are driven
through the edging strips into the
cabinet - the seal will straighten up
and sit flush to the cabinet when the
screws are fully home.
32
seal
front frame
door
handle
08 27348 00 - Howdens 70FP 25/4/07 7:43 Page 34