Data badge
- Lower part of front frame.
Type of gas
This cooker must only be used with either
Natural Gas only, or LP Gas only, as
specified on the appliance data badge.
Gas category
Natural Gas -
I
2H
, LP Gas -
I
3+
Pressure setting
G20 Natural Gas @ 20 mbar
G31 Propane @ 37 mbar
G30 Butane @ 28-30 mbar
Pressure test point
Use the oven injector.
Aeration -
Fixed.
Appliance class
Class 1, Freestanding
Countries of destination
GB - Great Britain, IE - Ireland
Electrical supply
230 - 240V ~ 50Hz
Warning:
This cooker must be earthed.
Spark generators
Two mains powered 6 outlet, one terminal
earthed out to chassis on one generator.
Grill
Grill burner is surface combustion type.
Spark gaps 3 - 4 mm.
Hob
Burners have burner heads and caps
which are removable for cleaning.
Concealed electrodes to each burner.
Ovens
Oven burners are sheet steel, with pierced
ports in stainless steel flame strip. Spark
gaps 3 - 4 mm. Flame supervision -
expansion type with fixed low rate bypass
drilling in valve (RHS oven); thermoelectric
type (LHS oven). Thermostat phial; front
centre of oven roof.
22
Gas
Burner
Nominal
Grammes per hour
Injector
Rate Qn
Butane
Propane
size
Natural Grill
2.4kW
-
-
1.15mm
Gas
Hob small x 2
1.0kW
-
-
72 “X”
medium x 4
2.0kW
-
-
100 “Z”
large x 2
2.9kW
-
-
1.1 “Y”
Ovens x 2
2.5kW
-
-
180 amal
Total heat input
∑
Qn 23.2kW
-
-
-
LP Gas
Grill
2.4kW
174g/h
172g/h
0.76mm
Hob small x 2
1.0kW
73g/h
72g/h
50
medium x 4
2.0kW
145g/h
143g/h
70
large x 2
2.9kW
211g/h
207g/h
85
Ovens x 2
2.4kW
174g/h
172g/h
70 amal
Total heat input
∑
Qn 23.0kW
1670g/h 1646g/h
-
Technical Data
Moving the cooker
Do not attempt to move the cooker by
pulling on the doors or handles. Open
the door and grasp the frame of the
cooker, taking care that the door does
not shut on your fingers.
Take care to avoid damage to soft or
uneven floor coverings when moving
the appliance. Some cushioned vinyl
floor coverings may not be designed
to withstand sliding appliances without
marking or damage.
Gas & Electrical connection
Please refer to installation instructions
for the Gas & Electrical Safety Regulations
and the Ventilation Requirements.
In your own interest, and that of safety,
it is the law that all gas appliances be
installed by competent persons. Corgi
registered installers undertake to work
to satisfactory standards.
Disconnection of gas and electric
appliances should always be carried
out by competent persons.
Warning:
This appliance must be
earthed.
If the ignition fails:
■
Check there is a spark when the
ignition button is depressed.
■
If there is no spark, check that the
electricity supply is switched on at
the socket.
■
Check that the gas supply is
switched on.
Stability bracket
If the cooker is to be fitted with a
flexible inlet connection, a stability
bracket should also be fitted to engage
in the back of the cooker. Make sure
this is re-engaged whenever you move
the cooker for cleaning.
The Gas Consumer Council (GCC) is
an independent organisation which
protects the interests of gas users. If you
need advice, you will find the telephone
number is your local telephone
directory under Gas.
The cooling fan
When the appliance is switched on,
you may hear the cooling fan come
on. This keeps the fascia and control
knobs cool during grilling / cooking
and will continue to operate for up to
15 minutes after the appliance has
been switched off.
During oven use the fan may cycle on
and off. Should any fault occur with
the cooling fan, the appliance will
require servicing. Contact Customer
Support.