Line up & Place the EMU on the screw heads and slide it down.



Ensure that the cable is properly routed back to the Power Box.

USING STOVE GUARD

The new Guardian model is a product that unites all three user selectable Stove Guard’s models: Now there is one model
that does it all.



The

Basic

model developed to satisfy most Home user’s needs.



The

Delay

model allows cognitive users to easily change settings, while thwarting a “button pusher” user attempts to

disable the device. (“Press & Hold” button when changing settings.)



The

Password

model version features password locking, for managed-care type situations. Administrators can set

the device to the User’s particular needs, and then password lock it.

The Stove Guard has 4 operating modes to control the stove: AUTO, TIMER, SG-OFF, and STOVE-OFF.

AUTO

This is recommended mode - provides the maximum protection & no further setting is required.

The AUTO mode allows the PIR (

motion detector

) in the EMU to automatically shut the stove off if the user is out of the

sensing area for longer than the preset time (

1 minute is the factory-preset time

). When the user re-enters the sensing

area

approximately 10-12 feet (3-4m) line of site from the EMU

, the Stove Guard will turn the stove back on and reset

timer to the last preset time. There is no need to reset the timer each time.
The green AUTO indicator lights. Green movement indicator lights every time when movement is detected and resets
clock to the preset time. Display will show number of minutes left before Stove Guard turn off the stove if no movement is
detected. If no movement is detected (user turn on the stove and left kitchen) for the preset time Stove Guard will turn off
the stove, display will show

00

and red Stove Off indicator (#12 on EMU diagram) lights. The display will show

--

when

neither top stove nor oven is turned on (no current is detected for more then 4 minutes and 40 seconds).

TIMER

The green TIMER indicator lights. In TIMER mode stove will operate for preset time (default is 5 minutes), which can be
adjusted to the cooking time of specific dish. Once the preset time is over, the stove will turn off. Display shows number of
minutes left before Stove Guard turns off the stove. When decimal point between digits lights display shows hours and
tenth of hours left (if countdown time is above 99 minutes). Movement detection is disabled in timer mode.

SG-OFF

The red SG OFF indicator lights. When the Stove Guard is in the SG-OFF (Stove Guard Off) mode the stove retains its
regular function, and the Stove Guard’s safety features are inactive. The display is blank. For safety reason one hour after
Stove Guard is in the SG-OFF mode and the stove is turned off (current is not detected) Stove Guard automatically goes
back to AUTO mode.

STOVE-OFF

The red STOVE-OFF indicator lights. When the Stove Guard is in STOVE-OFF mode the stove is turned off (same as
unplug the power cord). The display is blank.

HOW TO ADJUST THE STOVE GUARD

[1] SG-OFF button

When holding for 3 seconds change Stove Guard mode to SG-OFF.

Pressed instead holding for STANDARD model.

[2] AUTO button

When pressed turns the Stove Guard in AUTO mode and resets preset time.

Summary of Contents for Guardian COOKTOP

Page 1: ...last setting STOVE GUARD also can be used in a TIMER mode to set a maximum cooking time after which the stove will be automatically turned OFF IMPORTANT WARNING Installation of the STOVE GUARD COOKTOP Model requires a licensed Electrician to be wired properly according to local electrical codes Do not disassemble any of the components There are no user serviceable parts inside Refer servicing to a...

Page 2: ...utton 4 TIMER MODE button 5 TIME ADJUST button in 10 minute intervals 6 TIME ADJUST button in 1 minute intervals 7 SG OFF Indicator LED 8 MOVEMENT indicator LED for PIR 9 TIMER MODE indicator LED 10 AUTO MODE indicator LED 11 Motion Sensor window for PIR 12 STOVE OFF indicator LED 13 TIME display 14 Sensor height level adjustment screw to raise or lower the sensor s field of view Normally does not...

Page 3: ...ED should light Green Sensor LED will light when movement is detected A time of 01 minute should appear on the display A time of 1 minute is the factory default preset Wait about 20 seconds till display shows Dashes means that there is not current detection the stove doesn t draw current Turn on a burner Stove Guard should detect current display will show 01 Test the Stove Guard by standing out of...

Page 4: ...l show number of minutes left before Stove Guard turn off the stove if no movement is detected If no movement is detected user turn on the stove and left kitchen for the preset time Stove Guard will turn off the stove display will show 00 and red Stove Off indicator 12 on EMU diagram lights The display will show when neither top stove nor oven is turned on no current is detected for more then 4 mi...

Page 5: ...set the device to the User s particular needs and then password lock it If buttons are locked only the unlock function is enabled To lock unlock Stove Guard s buttons While holding SG OFF button press and hold RIGHT TIME button for 3 seconds Display will show L for lock or U for unlock function depend of previous lock unlock state User has 25 seconds to enter each of four digits 1 to 6 button SG O...

Page 6: ...tomatically to AUTO Auto On disabled Add 3 Current detection disabled assume always current Add 6 Disabling the current detection is not recommended Turn this setting on only if current detection doesn t work Stove Guard model choose one Standard Add 0 Delay Add 1 Password Add 2 Possible left digit settings 0 8 Right digit meaning Start calculation with 0 Red SG OFF LED meaning choose one Lights w...

Page 7: ...ent The sensing range of the EMU Electronic Monitoring Unit is over 4 meters around 12 feet at a radius of 110 degrees Each time the motion sensor is activated the green INDICATOR LED flashes 8 on EMU Diagram STOVE GUARD features an adjustable sensing height level to prevent the activation of the stove by small children or pets that might be detected by the motion sensor PIR There is a screw locat...

Page 8: ...the defective product if returned to SGI within the warranty period and with proof of purchase All STOVE GUARD devices are tested and inspected three times by a qualified electrical inspector and by our own factory before they are packed and shipped STOVE GUARD has been inspected by QPS Field Evaluation Services authorized Agency of Intela Inc Evaluation based on CSA model code SP 1000 for sale in...

Page 9: ...F E D C B A BLUE BLACK GREEN WHITE RED ORANGE Number 4 Rev Save on Security POWBOXFS PDF File Project Title POWER BOX Fail Safe Stove Guard 1 1 Page September 2006 Date TRANSFORMER T1 7 6 5 2 1 SWITCH_DPDT S1 6 5 4 3 2 1 STEERING_RELAY K3 5 4 3 2 1 POWER_RELAY K2 5 4 3 2 1 POWER_RELAY K1 5 4 3 2 1 JP2 RED BLACK WHITE GREEN JP1 GREEN WHITE BLACK RED CABLE_TO_MONITOR J2 6 5 4 3 2 1 CASE J1 GND GND G...

Page 10: ...e 10 of 10 User has to add wires drawn in this picture Phase 1 drawn in red Phase 2 black Ground green Neutral yellow white wires in real Transformer Current transformer through House s Power To the Stove ...