HE200 - Installation and Operation Manual
61
8.7
Chimney Support Installation
8.7.1
Universal Roof Support
This support has three possible uses:
1.
It must be used on a roof to support the chimney.
2.
It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.
3.
It may be used on a floor, ceiling or roof as a supplementary support.
For roof support installation, refer to the instructions provided with the support by Olympia Chimney who
provide the maximum height of chimney that can be supported by the support. Make sure you respect
those parameters.
8.7.2
Universal Offset Support
This support is used to support the chimney above an offset. When the chimney offset is used to pass
through a wall, this support may be used on the wall to support the chimney. For offset support installation,
refer to the instructions provided with the support by Olympia Chimney who provide the maximum height
of chimney that can be supported by the support. Make sure you respect those parameters.
8.8
Installation Instructions for Masonry Application
WARNING:
BEFORE STARTING THE INSTALLATION, THE MASONRY CHIMNEY MUST BE INSPECTED BY A
QUALIFIED SWEEP.
The following requirements must be respected:
1.
The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing
bricks that could inhibit correct installation of the liner.
2.
The clearance to combustible must be a minimum of 1" between the outside of the masonry and any
wood framing or loose insulation.
3.
The chimney must be built in accordance with the current building code.
4.
No other appliance can be connected to the same chimney.
Installation:
The chimney must be relined with a Forever Flex or Hybrid stainless steel liner of the same diameter as
the outlet of the fireplace. Only a connection at 30
°
or 45° angle is allowed. A special connector (B) must
be used to connect the liner (C) to the insulated chimney (A).
Summary of Contents for VB00003
Page 10: ...10 HE200 Installation and Operation Manual 6 142mm FORCED AIR DISTRIBUTION KIT 3...
Page 36: ...36 HE200 Installation and Operation Manual...
Page 56: ...56 HE200 Installation and Operation Manual Direct installation Exterior offset installation...
Page 89: ...HE200 Installation and Operation Manual 89 APPENDIX 7 EXPLODED DIAGRAM AND PARTS LIST...