16
Appendix A - Specifications/Dimensions
StorCase Technology Inc.
DE300i-SWC User's Guide - Rev. A00
SCSI Data Express subsystems conform to the Small Computer Systems Interface (SCSI)
Standard set by the American National Standards Institute (ANSI).
(1)
With carrier removed.
Appendix A - Specifications/Dimensions
Environmental Specifications
Operating
Storage
Ambient Temperature
-5° C to 50° C
-45° C to 75° C
Relative Humidity
(1)
10% to 80%
10% to 90%
Altitude
-1000 to 50,000 ft
-1000 to 50,000 ft
-304m to 15240m
-304m to 15240m
Shock
(2)
10g60g
(1)
Non-condensing with maximum gradient of 10% per hour.
(2)
11 msec pulse width 1/2 sine wave.
Physical
Specifications
Carrier
Receiving Frame
Height
1.07" (27.2mm)
3.38" (85.9mm)
Width
4.67" (118.6mm)
5.88" (149.4mm)
Depth
6.06" (153.9mm)
6.55" (166.4mm)
Weight
0.75lb (0.34kg)
2.1lb (0.95kg)
(1)
Chassis Reliability/Maintainability
MTBF
500,000 Hours
MTTR
5 Minutes
Preventive
Maintenance
None
Electrical Specifications
Input
+5V
200mA
+12V
1.2
m
A